Gas Testing

  • Home
  • Testing
  • Gas Testing
GLOBAL NETWORK OF ISO/IEC 17025 ACCREDITED LABS – 199+ LABS

Gas Testing Services Through a Worldwide Network of ISO/IEC 17025 Accredited Laboratories

What is Gas Testing? Gas testing is quantitative analysis of natural gas, LPG, LNG, feed gas, sweet gas, sour gas, biogas, biomethane, hydrogen, industrial & specialty gases to determine composition, calorific value BTU, Wobbe Index, H2S, mercaptan, moisture, hydrocarbon dew point per GPA 2261, ASTM D1945, ISO 6976, EN 27919, ISO 10715, GPA 2166.

Middle East • North Africa • Far East • Subcontinent • Europe • Americas | 48H TAT | Chain of Custody ISO 14912

ISO 17025 Accredited GPA • ASTM • ISO Methods EGAC • EIAC • GAC • PNAC • UKAS • A2LA
Accredited Test Labs - Gas Testing Lab with logo on wall and uniforms merged with gas sampling in oil field - technician holding sample cylinder with ATL logo on coveralls
ISO 17025
EGAC • PNAC
GPA 2261
ASTM • ISO
48H TAT
CoA Report
Middle East
SAC/DAC/QAC
Far East
SAC/TISI/MQA
America/Canada
USAC/SCC
Our worldwide network of gas testing laboratories delivers accurate, reliable analytical services through qualified facilities with relevant regional and international accreditations, including ISO/IEC 17025, where applicable. We connect businesses with trusted testing solutions to ensure quality assurance, regulatory compliance, and informed decision-making across global markets.

Complete Gas Testing Portfolio

Complete Gas Testing Packages with parameters and test methods.

Natural Gas Testing – BTU, Wobbe, Specific Gravity, Compressibility AGA-8, H2S ASTM D6228, Mercaptan, Moisture ASTM D1142, CO2, O2, N2
Sweet / Sour / Feed Gas – Sweetening efficiency, Amine carryover, Total Sulfur COS CS2, C14+ for gas processing inlet
Biogas & Biomethane – CH4, CO2, O2, N2, H2S, Siloxanes D4/D5, VOCs, NH3 per EN 16723, carbon credit
Hydrogen Purity ISO 14687 – Fuel Cell 99.97% – S, CO, CO2, O2, H2O, THC for NEOM, Suez H2 corridor
Need EGAC, EIAC, PNAC Accredited Gas Test Report in 48 Hours? Get a Quote

Gas Sampling & Chain of Custody Procedure (ISO 10715, GPA 2166, ASTM D4057, D1265, GPA 2174)

a) Pre-Sampling Requirements

Purge minimum 5x dead volume. Dead volume = (π*d²/4)*L. H2S safety <10ppm TLV, personal H2S monitor mandatory per OSHA. Cylinder validation per DOT-SP 2080, hydrostatic test within 5 years, valve type CGA 350 for H2S. Regulator heating 60-80°C for wet gas to avoid retrograde condensation. Filter 2 micron to remove particulates.

b) Sampling Methods (GPA 2166)

Spot sampling for pipeline QC, Composite per GPA 2166 for custody transfer accounting, Continuous for process control. Floating piston cylinders with constant pressure (GPA 2166) to maintain single phase. Sulfinert® treated cylinders mandatory for H2S, Mercaptan, COS, CS2 to avoid adsorption losses – verified per ISO 10715 Annex.

c) Natural & Feed Gas – Wellhead & Pipeline

Direct from wellhead, separator, pipeline via pitot-type probe per ISO 10715. Insert probe at center 1/3 of pipe diameter, facing upstream. Flow velocity 5-10 m/s optimal. For high pressure >70 bar, use double block and bleed manifold per API MPMS. Heat trace sampling line for C14+ rich gas.

d) LPG / LNG – ASTM D1265 & GPA 2174

LPG: ASTM D1265 piston cylinder, avoid water displacement, GPA 2177 for C3/C4. Cool cylinder to -20°C before filling. Fill 80% liquid max per DOT 49 CFR. LNG: GPA 2174 cryogenic piston sampler, vaporization at 30°C per ISO 8943, sample to 150 bar buffer. No free sampling kit – DOT cylinders not free.

e) Documentation – Chain of Custody per ISO 14912

CoC Form: Sample ID, Date/Time UTC, Pressure psig/barg, Temperature °C, Location GPS coordinates, Well/Platform/Terminal name, Operator Name & Company, Cylinder No. & Serial, Lab ID, Field H2S reading, Purging time, Ambient conditions. LIMS barcode tracking. Photos of sample point, cylinder tag, gauge reading mandatory.

f) Transportation – UN & DOT Compliance

UN pressure vessel compliance, DOT-3E 1800 psi, DOT-3AA 2400 psi for sour gas. Valve protection cap metal, pressure relief burst disc 3000 psi. Label per IMDG/IATA: UN 1971 Natural Gas Compressed, UN 1075 LPG, UN 1972 LNG. Shipper declaration, SDS, CoC attached. Cylinder tracking via RFID/barcode, GPS logger for LNG.

g) Lab Receipt & Preservation

Leak check with Snoop leak detector, pressure log vs field pressure, temp equilibration 20±2°C for 4 hrs per GPA 2166. Analysis within 7 days for H2S/mercaptan per GPA 2166 stability limit, 14 days for C6+ composition. Sulfinert cylinders retain H2S 30 days. Client to arrange DOT-approved cylinders or rent/purchase at cost from ATL network. No free sampling kits per company policy.

⚠️ Policy Note: Sampling cylinders, regulators, heated lines, Sulfinert cylinders are NOT provided free. Client arranges DOT-approved cylinders or rents from ATL network at cost. Purchase options: DOT-3E 500cc to 1000cc Sulfinert. No free kits. Safety: H2S PPE per OSHA 1910.134 mandatory.

Global Coverage and Accreditations All Regions

KSA • UAE • Oman • Qatar • Kuwait • Bahrain • Egypt • Turkey • Lebanon • Iraq • Iran • Subcontinent (India + Pakistan)

🇸🇦 KSA – Saudi Arabia

Ports: Jubail, Yanbu, Ras Tanura

Accred: GAC + Aramco Approved, SASO

Field: Ghawar, Shaybah | GPA 2261 • Aramco SAES-A-007

🇦🇪 UAE – United Arab Emirates

Ports: Jebel Ali, Fujairah, Ruwais

Accred: EIAC, ENAS + ADNOC Approved

Field: Bab, Bu Hasa | ESMA • GPA 2261

🇴🇲 Oman

Ports: Sohar, Duqm, Qalhat LNG

Accred: OAC + PDO Approved, DGSM

Field: Sohar Refinery • Sohar Industrial

🇶🇦 Qatar

Ports: Ras Laffan, Mesaieed, Hamad

Accred: QAC + QatarEnergy LNG Approved

Field: North Field • ISO 6976 • LNG Export

🇰🇼 Kuwait

Ports: Al Ahmadi, Shuwaikh, Shuaiba

Accred: KOWAC + KPC/KNPC Approved

Field: Burgan • Kuwait Std • GPA

🇧🇭 Bahrain

Ports: Sitra, Khalifa Salman, BAPCO

Accred: BSMD + BAPCO Approved

Field: Bahrain Field • Rigs Lube Sampling

🇪🇬 Egypt – North Africa

Ports: Alexandria, Port Said, Suez Adabiya

Accred: EGAC ISO 17025 + EGPC/EGAS, GASCO

Field: Idku LNG, Damietta • ES 1001 • EEAA

🇹🇷 Turkey

Ports: Ceyhan, Aliaga, Dortyol

Accred: TURKAK + BOTAS Approved

Field: Ceyhan Terminal • EN 27919 • TANAP

🇱🇧 Lebanon

Ports: Beirut, Tripoli, Zahrani

Accred: COLIBAC / LIBNOR + MoE

Field: Zahrani Terminal • IAQ • VOC

🇮🇶 Iraq

Ports: Umm Qasr, Basra, Khor Al Zubair

Accred: NCCI + Basra Oil Company Approved

Field: Rumaila, West Qurna • GPA 2261

🇮🇷 Iran (Partner Network)

Ports: Asaluyeh, Bandar Abbas, Mahshahr

Accred: NACI + NIGC via partner (compliant)

Field: South Pars • Asaluyeh • Partner Lab

🇮🇳🇵🇰 Subcontinent – India + Pakistan

Ports: Mundra/Dahej LNG + Port Qasim/Gwadar

Accred: NABL India + PNAC Pakistan, PSQCA

Field: Bombay High + Sui/Qadirpur • SSGC SNGPL

EUROPE | AMERICA | AUSTRALIA | CENTRAL ASIA

Extended Global Network: Far East: Singapore SAC-SINGLAS, Malaysia SAMM, Indonesia KAN, Thailand TISI, Korea KOLAS, Japan JAB, China CNAS | Europe: UK UKAS, Germany DAkkS, Netherlands RvA, Norway NA, Turkey TURKAK | Americas: USA A2LA PJLA Houston TX Louisiana, Canada SCC, Brazil CGCRE, Mexico EMA, Australia NATA

Gas Testing FAQs

What is EGAC accredited gas testing in Egypt?

EGAC ISO/IEC 17025 at Alexandria, Dekheila, Port Said East/West, Suez Adabiya, Ain Sokhna, Damietta, Safaga, Ras Shukheir, El Hamra, Abu Qir, Idku LNG per ES 1001, GPA 2261, ISO 6976, approved EGPC, EGAS, GASCO, EEAA. 48H TAT.

Where to get PNAC accredited natural gas testing in Pakistan?

PNAC ISO 17025 for BTU, Wobbe, H2S at Karachi KPT, Port Qasim, Bin Qasim LNG, Gwadar, Ormara, Hub, Sui Kadanwari Qadirpur Zamzama Sawan Miano Mari, PSQCA, HDIP, SSGC/SNGPL, OGRA CNG Karachi Lahore Islamabad.

What is difference between GPA 2261 and ASTM D1945?

GPA 2261 routine field C6+ via GC, ASTM D1945 referee with more precision. Both calculate BTU, SG, Wobbe via GPA 2172 / ISO 6976 / D3588. GPA 2261 faster for custody.

How is LPG tested at Port Qasim Pakistan and Alexandria Egypt?

ASTM D2163 composition C3/C4, D1267 vapor pressure, D2158 residue, D1838 copper corrosion, D1657 density. Cylinder per D1265 floating piston, 80% fill max DOT, Sulfinert for mercaptan. HD-5 spec. PNAC/EGAC.

What are EGAS and EGPC approved labs for gas analysis in Egypt?

EGAS & EGPC approve EGAC labs for C6+, feed gas C14+, LPG, LNG per ES 1001, GPA 2261. Labs at Alexandria, Suez, Port Said, Idku LNG, Damietta. ATL partner via EGAC.

What is H2S limit in natural gas per ISO 19739 and GPA?

ISO 19739: Max 5 mg/m3 H2S pipeline quality, 2 ppm LNG feed per ISO 14687. GPA 2261 reports H2S. ATL via D6228 SCD 0.02-20 mg/m3, UOP 163, GPA 2377. Sulfinert mandatory.

How to test LNG at Alexandria and Idku LNG ports?

GPA 2174 cryogenic piston, vaporization 30°C per ISO 8943, C1-C6+ BTU Wobbe per ISO 6976, EGAC CoA for Idku, Damietta, Ain Sokhna, custody transfer, 48hr TAT, ISO 14912 CoC.

What is Wobbe Index and why important for Europe?

Wobbe = HV / sqrt(SG). Critical for burner interchangeability per EN 437, EN 16726. ATL reports Gross/Net Wobbe per ISO 6976, GPA 2172 for EU grid entry, UK UKAS, DE DAkkS, NL RvA, TR TURKAK.

Which accreditation required for gas testing in Saudi Aramco?

GAC ISO 17025, SASO approved, Aramco vendor code, SAES-A-007, SAES-A-034, GPA 2261, ASTM D5504 sulfur, lab approval Jubail, Yanbu, Ras Tanura, Ghawar, Shaybah. ATL via GAC.

What is sampling cylinder requirement for sour gas with H2S?

DOT-3E 1800psi or DOT-3AA 2400psi Sulfinert per GPA 2166, floating piston for >10% C6+, heated regulator 60-80°C, purge 5x dead volume, H2S monitor <10ppm TLV, PPE OSHA 1910.134. No free cylinders – rent at cost.

How long does EGAC report take in Suez?

Standard 48-72 hrs C6+ BTU Wobbe, 24 hrs express GPA 2261, same day BTU only. EGAC stamped CoA ES 1001, GASCO, EGPC, EGAS. Sampling Suez Adabiya, Ain Sokhna, Alexandria, LIMS tracked.

What is cost of ISO 17025 BTU analysis in Middle East?

Cost depends upon required testing parameters including C6+/C14+/C36+ scope, sulfur, dew point, accreditation EGAC/EIAC/GAC/ENAS/PNAC, TAT, technical advisory. Contact [email protected] for tailored quotation – 24H response. No fixed price.

Do you provide CNG testing Karachi, Lahore, Islamabad?

Yes, OGRA CNG Rules 1992, ISO 6976 BTU, H2S D6228, moisture D1142, odorant per OGRA, PNAC lab Port Qasim, Sui fields, SSGC/SNGPL network Karachi Lahore Islamabad Multan Faisalabad.

What is turn-around time for report?

Standard 48-72 hrs C6+ composition BTU Wobbe, 24 hrs express GPA 2261 routine, same day BTU only. EGAC/EIAC/GAC/ENAS/PNAC stamped CoA, LIMS tracking, ISO 14912 CoC, portal access.

Which method for mercaptan and odorant?

ASTM D6228 SCD, UOP 212, ISO 19739, GPA 2377 for mercaptans, THT, TBM odorant. Sulfinert cylinders, GPA 2166 sampling, analysis within 7 days. Critical for city gas safety.

Can you test at Jubail, Yanbu, Jebel Ali, Fujairah?

Yes, GAC KSA Jubail Yanbu Ras Tanura Jeddah Dammam Rabigh, EIAC ENAS UAE Jebel Ali Fujairah Ruwais Abu Dhabi, Aramco ADNOC approved, GPA 2261, D1945, ISO 6976, SASO, ESMA. 24/7 sampling.

What is hydrocarbon dew point?

HC dew point is temp at which heavy HC condense from gas, calculated via C14+ or C36+ extended GPA 2286, ISO 23874, Peng-Robinson EOS. Critical for pipeline, LNG feed to avoid liquid dropout, compressor damage.

Do you provide LNG testing at Ras Laffan and Asaluyeh?

Yes, GPA 2174 LNG sampling, ISO 8943, ISO 6976 BTU Wobbe, QAC QatarEnergy at Ras Laffan, NACI NIGC via partner for Asaluyeh Bandar Abbas Mahshahr South Pars, custody transfer, 48H TAT.

What accreditation for Oman and Qatar?

Oman: OAC, DGSM, PDO approved Sohar Duqm Qalhat. Qatar: QAC, QatarEnergy LNG approved Ras Laffan Mesaieed. Both ISO 17025, GPA 2261, ISO 6976, 48H TAT.

How to collect gas sample safely per ISO 10715?

ISO 10715: purge 5x dead volume, pitot probe at 1/3 pipe diameter, flow 5-10 m/s, heated regulator 60-80C, Sulfinert for H2S, H2S monitor, PPE, CoC with GPS P/T, no free cylinders – rent at cost.

What is feed gas vs sales gas testing?

Feed gas inlet to gas/LNG plant heavier C6+ C14+ up to C36+, high H2S CO2, extended GPA 2286. Sales gas pipeline spec C6+ BTU Wobbe H2S <5mg/m3 per ISO 19739 after processing. Both via GPA 2261.

Request Your Accredited Gas Testing Quote Today

KSA • UAE • Oman • Qatar • Kuwait • Bahrain • Egypt • Turkey • Lebanon • Iraq • Iran • Pakistan • India | 24/7 Sampling | ISO 17025 CoA | 48H TAT | EGAC • EIAC • ENAS • GAC • PNAC • NABL • UKAS • A2LA

Get a Quote
Email: [email protected] | Website: www.accreditedtestlabs.com | Gas Testing: C6+ | Feed Gas C6+ | C14+ | C36+ | LPG | LNG | Biogas | H2S | Hydrogen

Accredited gas testing laboratory near me in: KSA Jubail Yanbu Ras Tanura Jeddah Dammam Rabigh Ghawar Shaybah GAC Aramco SASO | UAE Jebel Ali Fujairah Ruwais Abu Dhabi Khor Fakkan Sharjah EIAC ENAS ADNOC ESMA Bab Bu Hasa | Oman Sohar Duqm Salalah Muscat Qalhat LNG OAC PDO DGSM | Qatar Ras Laffan Mesaieed Hamad Al Ruwais QAC QatarEnergy North Field | Kuwait Al Ahmadi Shuwaikh Shuaiba KOWAC KPC KNPC Burgan | Bahrain Sitra Khalifa Bin Salman BSMD BAPCO Bahrain Field | Egypt EGAC Alexandria Dekheila Port Said East West Suez Adabiya Ain Sokhna Damietta Safaga Ras Shukheir El Hamra Abu Qir Idku LNG Hamrawein ES 1001 GASCO EGPC EGAS EEAA | Turkey Ceyhan Aliaga Izmit Dortyol Marmara Ereglisi TURKAK BOTAS TANAP | Lebanon Beirut Tripoli Zahrani COLIBAC LIBNOR MoE | Iraq Umm Qasr Basra Khor Al Zubair Faw NCCI Basra Oil Rumaila West Qurna | Iran Asaluyeh Bandar Abbas Mahshahr Lavan NACI NIGC South Pars | Pakistan PNAC Karachi KPT Port Qasim Bin Qasim LNG Gwadar Ormara Keti Bandar Hub Sui Kadanwari Qadirpur Zamzama Sawan Miano Mari SSGC SNGPL OGRA PSQCA HDIP | India NABL Mundra Kandla JNPT Mumbai Hazira Dahej LNG Kochi Chennai Vizag Paradip Haldia ONGC GAIL PNGRB | Far East Singapore SAC-SINGLAS Jurong Malaysia SAMM Indonesia KAN Thailand TISI Korea KOLAS Japan JAB China CNAS | Europe UK UKAS London Aberdeen Rotterdam Hamburg DAkkS RvA NA | Americas USA A2LA PJLA Houston LA Texas Canada SCC Brazil CGCRE Mexico EMA Australia NATA. Natural Gas C6+ C14+ C36+ Feed Gas LPG LNG Sweet Sour Gas Biogas Hydrogen Testing ISO 6976 GPA 2261 2286 ASTM D1945 D2163 D6228 D5504 D1265 GPA 2174 ISO 8943 EN 16723 ISO 14687 ISO 10715 GPA 2166 ASTM D4057.


IFIA Certified Labs, ISO Certified Labs

Natural Gas Sampling and Testing Services
Natural Gas testing and sampling is one of the the most crucial tasks in the field of testing where high risk of life-taking hazards is involved. However, following predefined exact procedures always lead to safe and sound operations. Accredited Test Labs always care for the kind of concern and uses procedural manuals to accomplish work. Here is a list of all kinds of Gas Testing and Sampling as per accredited and authorized procedures.

We have a proven track record in both local and global projects including entire Middle East, Far East, Africa, and Asia. We are expanding to USA and UK/Europe as well through our most competitive and proficient services.