• Home
  • Archive by category "Stake Emission Testing"

VOC Emission Testing in Jeddah, KSA

Enquiry:

Please find below details of the item required against the subject inquiry and submit your offer within 48 hours.

You are requested to kindly quote with your least bottom price & minimum delivery time for items in respective quantities.

Kindly acknowledge receipt of this inquiry and do let us know if you require any further information by replying all to this mail.

We would like to conduct VOC emission testing for Futura classic ,a two component chemically curing aliphatic acrylic polyurethane . Please find the attached Technical Data Sheet (TDS) for your reference.

We kindly request the following information’s:

  • The procedure to initiate testing.
  • The estimated cost of the test.
  • The expected duration to receive the results.
  • The testing standards you follow.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Ambient Air, Stack Emission Testing in RAK, UAE

Enquiry:

We would also like to incorporate the following detailed testing and documentation for our submission to the RAK Government:

1. **Stack Emission Testing**

We require testing to be conducted on the main exhaust stacks, specifically before and after the filtration system. The parameters to be measured, using accredited laboratory methods (such as USEPA/EN standards), should include:

* Total Volatile Organic Compounds (TVOCs)

* Formaldehyde, Acetaldehyde

* SO₂, NOx, HCl, Cl₂

* Particulate Matter (PM₁₀ / PM₂.₅)

* Odor Concentration (OU/m³) – utilizing Dynamic Olfactometry (EN 13725)

The expected outcome for this testing is to demonstrate a clear reduction (≥ 80%) in odor-causing gases and particulates after the filtration system.

2. **Ambient Air Monitoring (Fenceline Study)**

For this, we request the placement of monitoring stations both upwind and downwind of our facility boundary. The monitoring period should be for 72 continuous hours, and the parameters to be measured include:

* TVOCs

* SO₂, NOx

* PM₂.₅ / PM₁₀

* Odor concentration

The expected outcome is to show no significant difference between downwind and upwind concentrations, thereby confirming effective odor control.

3. **Filtration System Performance Test**

We require measurements of pollutant concentrations at both the filter inlet and filter outlet to calculate the filtration efficiency (%) for each pollutant. The expected outcome is to document an efficiency of > 85% across key pollutants.

4. **Root Cause and Corrective Action Documentation**

We need documentation that addresses the root cause of odor emissions, which we’ve identified as being linked to VOCs and particulates during specific production stages. The corrective action taken is the installation of a multi-stage purification system (comprising pre-filters, ultraSORB chemical filters, and final filters). Additionally, preventive measures such as a scheduled maintenance and filter replacement plan, along with routine stack and ambient monitoring every 6 months, should be included.

5. **Deliverables for EPDA**

The final deliverables for submission to EPDA should include:

* Laboratory reports with before/after results.

* Graphs and tables clearly showing emission reductions.

* Photographs of the installed system and the monitoring setup.

* A comprehensive monitoring and compliance plan for ongoing reporting.

Could you please confirm if your company is recognized by the Ras Al Khaimah government/Municipality for these additional tests and provide an updated quote that incorporates these expanded requirements, including details on the cost and any other formalities? We are still aiming to schedule this as immediately as possible.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Noise, Air, and Emission Testing in Sri Lanka

Enquiry:

We are requesting to provide us with quotations for the below requirement

Requirement; BOUNDARY NOISE MEASUREMENTS (Day and Night Time) STACK EMISSION MEASUREMNTS (03 Boilers, LPG) STACK EMISSION MEASUREMNTS (Diesel Generator) AMBIENT AIR QUALITY OCCUPATIONAL EXPOSURE MONITORING (Lux, Noice, Temperature, Heat stress, Dust) (Inside) More infrormation please contact Mr Dasun 9470 6223 550

Kindly make sure you response to this request on/before Tomorrow before 5pm

if you have any further concern or clarification, please be free to contact me.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Sea Water, stake emission, noise test in Abu Dhabi, UAE

Enquiry:

Stack Analysis, Seawater Intake & Outfall samples collection & analysis and Noise Monitoring

We invite you to tender for the provision of above services in accordance with the following details:

1.  Tender package is attached herewith including RFQ Acknowledgment, Tender Documents, Visitor Request form, Scope of work, RFQ

2.  Tender Program / Schedule:

​DescriptionDateRemarks
RFQ Sent1st February 2024By Procurement via email
Site Survey TBA If required (Technical Officer)
Technical Query on Scope of work5th February 2024By Contractor via email
Clarification on Technical Queries7th February 2024By Technical officer to Contractor via email
Technical & Commercial Bid submission13th February 2024By Contractor via email

Any change in the above schedule for any reason will be communicated to you via email.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].