Cleaning Detergent Analysis in Saudi Arabia

Enquiry:

. I have a chemical detergent product I need a lab service to analysis the product in order to get the product formula and provide the product components (ingredient) along with percentage of each component. Do you provide this kind of service?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Testing for Desalination Plant, Abu Dhabi UAE

Enquiry:

We are currently having a Project (Job in Hand) with a client.

Project: Establishing a Desalination Plant and an Internal Irrigation Network For the Water Treatment Project in Abu Dhabi

We are approaching you to provide your best rate for the Water Quality Test at 5 locations (exact location will be confirmed later) location plan attached, please find the required test in table below for your reference.

MINIMUM WATER QUALITY TEST
PAREMETERS UNITRESULTSDRINKING WATER QUALITY STANDARDS RECOMMENDED VALUEREMARKS
Pathogens, biological agentsFaecal coliforms:cfu/100ml   
Total coliforms:cfu/100ml   
Suspended solidsTSS:ppm   
TDS:ppm   
Electrical Conductivity (dS/m @ 25°C)   
Faecal Coliform or E.Coli CFU or MPN / 100ml   
Helminth Ova Number / l   
Legionella CFU or MPN /ml   
Turbidity NTU   
Residual Chlorine
(Total Available)
     
Dissolved Oxygen ppm   
Salinity ppm   
Sodium Adsorption Ratio SAR   
Chloride ppm   
Sulphates ppm   
Nitrate ppm   
Sodium meq/l   
Calcium ppm   
Potassium ppm   
Carbonate ppm   
Bicarbonate meq/l   
Chemical and biological oxygen demandCOD:ppm   
BOD:ppm   
Boron ppm   
Toxic metalsAluminium:ppm   
Arsenic:ppm   
Beryllium:ppm   
Cadmium:ppm   
Chromium:ppm   
Cobalt:ppm   
Copper:ppm   
Fluoride:ppm   
Iron:ppm   
Lead:ppm   
Lithium:ppm   
Magnesium:ppm   
Mercuryppm   
Molybdenum:ppm   
Nickel:ppm   
Selenium:ppm   
Vanadium:ppm   
Zinc:ppm   
pH     
Note: Above Table format for Guidance only – Lab to develop better.

Highly appreciate to receive your Quotation ASAP


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Waste Water Analysis Contract, Qurrayah, KSA

Enquiry:

I would like to request a quote for a waste water analysis project for aramco.

Location: Quarraya, saudi arabia

Duration: 3 years

Please see the attached SOW. Any clarifications please let me know.

ItemParametersUnitsFrequencyLocation
 1Total Organic Carbone (TOC)mg/L
 2Benzenmg/LMonthly
 3Carbon tetrachloridemg/L
 4Total Chlorinated Hydrocarbonsmg/L 
 5Furansmg/LMonthly
 6Hexachlorobenzenemg/L
 7MTBEmg/LMonthly
 8Polycyclic Aromatic Hydrocarbons (PAHs)mg/L
 9Dioxinemg/LMonthly
 10Total Petroleum Hydrocarbons (TPH)mg/L
 11Vinyle chloridemg/L
 12Xylenesmg/LMonthly
ItemParametersUnitsFrequencySampling Location
 pH—D
 Total Dissolved Solids (TDS)mg/L
 Volatile Suspended Solids (VSS)mg/L
 Dissolved Oxygen (DO)mg/L
 Biochemical Oxygen Demand (BOD)mg/L
ItemParametersUnitsFrequencySampling Location
 Flowratem3/dayDaily
 pH —
 Total Suspended Solids (TSS)mg/LWeekly
 Biochemical Oxygen Demand (BOD)mg/L
 Total ColiformMPN/100 mlWeekly
 TurbidityNTU
 Oil and Greasemg/LAnnually
 Phenolsmg/L
 Aluminum (Al)mg/LAnnually

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Gold Content in Rock Sample Analysis in UAE

Enquiry:

We have two rock samples (Green and Brown Rocks) and would like to know if there is gold in them and, if so, how much gold % composition each sample contains.

Please provide us your best price for this test.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing Contract in Jubail, KSA

Enquiry:

Please provide your best price as per below.

Physical, Chemical and Dissolved Gas Analysis
Physical, Chemical and Dissolved gas analysis (DGA) of the insulating oil is useful in evaluating
transformer health. Further SOW for oil analysis is as follow,
Contractor should analyse the results obtained from Oil analysis based on ASTM D3613, ASTM
D3612, and ANSI/IEEE C57.104 or any other applicable standard approved from IEEE/IEC/ASTM
Below is the Lot # 1 with total No’s. of transformers for which Physical, Chemical & DGA should
be performed.

There are multiple transformers on multiple locations.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chemical Detergent Analysis in KSA

Enquiry:

I have a chemical detergent product I need a lab service to analysis the product in order to get the product formula and provide the product components (ingredient) along with percentage of each component. Do you provide this kind of service?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Bio Diesel Testing in Jeddah, KSA

Enquiry:

I look for a sampling and analysis service in Jeddah, Saudi Arabia with fast turnaround.

Samples will be taken from ISO tank (Top-middle-bottom):

Parameters and methods as below:

PARAMETERS TESTEDANALYSIS METHODS
Free Fatty Acid as Oleic %AOCS ca 5a-40orISO 660
Moisture & Volatile Matter %AOCS Ca 2b-38orISO 662
Insoluble impurities %AOCS Ca 3a-46orISO 663
Unsaponifiable Matter %AOCS Ca 6a-40orISO 3596
Sulphur ppm (Max)ASTM D5453
IODINE VALUEISO 3961

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].