Diesel Sample Testing in Kuwait

Enquiry:

Can you confirm if Accredited labs can also perform ASTM D975 analysis of diesel sample that includes UOP46 testing for wax, ASTM D2500 and ASTM D6371 / IP309.

Please consider this as urgent. Your earliest response will be highly appreciated.

Once confirmed, please submit a quote and also advise the amount of diesel required to carry out these tests, along with estimated time for analysis and results.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Wood Sample Testing, MDF Testing, Kuwait

Enquiry:

We requested need to do the following test on our wood sample in our Kuwait branch.do you have any testing lab facility for the wood if yes please send the quotation?  For other assistance please contact us.

  • Measure the thickness of the front fibers layers to see if they have an equal thickness or not.

We have two types of fronts attached to their data sheets:

  1. MDF base board coated with decorative paper on both sides and lacquered with UV treatment on its front face.
  2. Wood particle base board coated with decorative paper on both sides.

We are requesting these tests and we are facing a bending issue, especially in the MDF material that we are receiving from the supplier although we used to receive the same material from the same supplier with no bending.

So we doubt that the material composition has been changed somehow.

The supplier justifications the following:

After cutting a section from the front they found the below:

The front covering is 0,347 mm thick and the back covering is 0,547 mm. 

This means that there is one kraft paper under the decorative paper on the front side and two kraft papers on the backside. So, this asymmetrical configuration has produced bending over time.

This malfunctioning of the press occurs in a very isolated way affecting one or two boards and it is the reason for those 8 bent pieces.

This explains why you have found 8 bent pieces despite the new packing system.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Gas Cylinders on Rent in Kuwait

Enquiry:

We are requiring to rent or lease out 50 cylinders to sample gas from well-heads in Kuwait facility, to be mobilized to Kuwait in 3-4 weeks.  

Could we request you to provide us a commercial quote for the below subject.  Even if the quantity is lesser, you may respond.  Also, please specify the volume, pressure rating and coating-material to assess if it is suitable for helium analysis.  You could indicate any alternative receptacle for the purpose, as well.

The details of the requirement are as follows:

  • Stainless steel canisters 30 cc or alternate size (to 600 cc) to sample gas from well head or gathering centers for analysis of helium, pressure rated to atleast 1500 psig
  • Desirable if a 2-phase adapter or valves to reduce the pressure (which is usually high, apprx 8000-9000 psig, from the well head ).  
  • Subsequently, the cylinder would be subsampled with a hyperdermic needle at STP, hence suitable adapter, if available.

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Oil Contaminated Water Testing, Qatar

Enquiry:

Kindly furnish your Technical and Commercial proposal along with Service Duration for the subject job scope.

Scope:

Required parts / Service to rectify the defects (Material Description)QuantityUOM
contaminated oily water  laboratory Analysis 1. pH 2. COD 3. TSS 4. OIL And GREASE 5. SULFIDE 6. PHENOLS5pcs

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing Contract, Kuwait

Enquiry:

Please provide your best offer prices for the attached request for the Transformer Oil Analysis,

Please consider the number of samples approximate 20,000 -/ to provide your best price offer.

Tests (For Transformer Oil Analysis)Test Method
AppearanceExamined Visually At Ambient Temperature
Visoos ty Ai 40 °cIS03 104 Or ASTM D445
Visoos ty At —30 °cIS03104 Or ASTM D445
Pour Point 0cIS03016 Or ASTM D97
Demity At 20 °cIS03675 Or ISO12185
Water ContentIEC.60814 Or ASTM D1533
Dielectric Strength (Breakdown Voltage)IEC.60156 Or ASTM D1298
Dielectric Dissipation Factm (DDF) At 90 °cIEC.6024
AcidityIEC.6202 1— l   Or ASTM D974
Aniline Point 0cASTM D66l
Interfacial Tension at 20°cISO,   6295 Or ASTM D971
Total Sulphur ContentBS 2000 Part 373 Or ISO 14596
Corrosive SulpherIEC.62534 And ASTM D I275 B
Inhibitor ContentIEC.60666
Fmrfural ContentIEC61 198
Oxidation StabilityIEC61125C, Telst Duration 164 Hour , If Inhibitor Content Is <0.01% (Note 1) IEC60247
Total Acidity
Sludge
-Dielectric Dissipation. Factm At 90°c
Flash PointISO2719
Polycyclo Aromatic Content (PCA)BS2000 Part 346
PCB ContentIEC61619

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Oxygen Testing in Kuwait

Enquiry:

We need to analyze Liquid Oxygen (Pure- 99.6%, Type II) sample against the impurities mentioned in the attachment – standard excerpt from MIL-PRF-27210J.

Kindly advise the feasibility and the techno commercial offer for the same.


One of our highly competent lab in Kuwait would be taking over this job.