• Home
  • Archive by category "Al Khobar"

Calibration Services in Khobar, KSA

Enquiry:

Could please send me the quotation for the below listed items.

1-Flowmeter : we have 4 no’s of flowmeter.

Equipment nameModelSerial NoServices
Flow Meter120031897/1Calibration
Flow Meter120026518/2Calibration
Flow Meter120032236/2Calibration
Flow Meter120032048/2Calibration

2- Sampling Pump-

Equipment NameModelSerial NoServices
Sampling Pump16000 HJS HOLDINGS016653Charging Problem
Sampling Pump16000 HJS HOLDINGS016654Charging Problem
Sampling PumpHJS HOLDINGSNAMaintenance
Sampling PumpHF812NAMaintenance
Sampling PumpHF812NAMaintenance
Sampling PumpHF812NAMaintenance
Sampling PumpHF812NAMaintenance
Sampling PumpHF812NAMaintenance
Sampling PumpHF812NAMaintenance

3- Lab Equipment

NO.DESCRIPTIONMODEL / SERIAL NUMBERQTYUOMDEFECTS
1Bigneat Filter HoodBC8004105 / SN714751UnitFilter is not working anymore. (need to change filter set-up)Missing plugNo calibration record and historical dataNo smoke test recordNon-conformance instrument.
2Stereo MicroscopeMeiji EMS1UnitMissing eye pieceNo need for calibration but this instrument requirement preventive maintenance, cleaning, and pressurized air drying.
NO.DESCRIPTIONMODEL / SERIAL NUMBERQTYUOMDEFECTS
3Polarized Light MicroscopeMT6120 / SN1167411UnitNeed to have new graticule piece for alignment of scope and for daily calibration.Advise for dry cleaning and maintenance.
4Phase Contrast MicroscopeML6520 / SN116739 SN1167383UnitNeed to have new graticule piece for alignment of scope and for daily calibration.Advise for dry cleaning and maintenance.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Quality Analysis in Al Khobar, KSA

Enquiry:

I am reaching out to you to enquire if the list of attached tests for analysing the water quality under your scope of work. If so, please send us your best priced quotation for 2 samples at the earliest possible. I would also like to know about the sample turnaround time. The samples can be submitted at your location in KSA.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Hotel Food, Ice, Swabs Testing in Jeddah, KSA

Enquiry:

We are in need of below services for our restaurant in Riyadh/Jeddah/Khobar.

  1. One hand swab from any food handler
  2. One surface swab ( from workstations or chopping board/knives etc.)
  3. 2 food items (1 RTE sauce/Salad/sanitized vegetables and 1 Beef patty – medium or med.well)
  4. Ice or water sample

Kindly let us know if this is something you provide as service.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Sewage Water Testing in Al Khobar, KSA

Enquiry:

Please provide us your best quote for below Sewage sample analysis.  

The following Parameter to be analyzed of Sewage Sample.

Physical Parameters

pH : 6.5 – 9.0
Turbidity : 2 N.T.U.
Total Dissolved Solids : 3500 mg/l
Total Suspended Solids : 10 mg/1
temperature : DT +/-3
Floating Particles : Nil

Chemical, Organic & Inorganic

B.O.D. : 10 mg/1
Ch. Oxygen Demand : 40 mg/1
Dissolved Oxygen : MINIMUM 5 mg/1
Fat, Oil and Grease (Emulsified) : 5 mg/1
Ammonia(As Nitrogen) : 1 mg/1
Nitrate (NO3) as N : 5 mg/1
Nitrite (NO2) as N : 0.5 mg/1
Total Kjeldahl Nitrogen : 5 mg/1
Total Nitrogen : 10 mg/1
Total Organic Carbon (TOC) : 10 mg/1
Sulphate : 300 mg/1
Sulphide : 0.05 mg/1
Residual Chlorine : 0.5 mg/1
Total Phosphate (P) : 1 mg/1

Microbiological

Total Coliforms : <2.2 colonies/100 ml l
Helminth eggs : <0.1/1000ml egg/l
Parasitic Helminth Worms : Absent worm.L

Inorganic Compounds and heavy metal

Fluorescent Petroleum Materials : 0.1 mg/l
Hydrocarbons : 5 mg/l
Phenols : 0.002 mg/l
Chlorides : 1500 mg/l
M.B.A.S : <5 mg/l
Aluminium : 1 mg/l
Copper : 0.2 mg/l
Iron : 1 mg/l
Nickel : 0.1 mg/l
Lead : 0.1 mg/l
Cadmium : 0.01 mg/l
Total Cyanide : 0.05 mg/l
Zinc : 0.5 mg/l
Total Chromium : 0.02 mg/l
Cobalt : 0.05 mg/l
Manganese : 0.2 mg/l
Bicarbonate : 400 mg/l
Sodium : 200 mg/l
Magnesium : 60 mg/l
Calcium : 200 mg/l
Sodium Absorption Ratio : 6 mg/l
Beryllium : 0.1 mg/l
Fluorides : 1.5 mg/l
Lithium : 2.5 mg/l
Selenium : 0.05 mg/l
Vanadium : 0.1 mg/l
Barium : 2 mg/l
Mercury : 0.001 mg/l
Molybdenum : 0.01 mg/l
Boron : 1 mg/l
Arsenic : 0.05 mg/l


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].