TBC (Total Bacterial Count) and Legionella testing are two different types of microbiological water tests, each serving a different purpose.
1. TBC (Total Bacterial Count)
Also called:
Total Viable Count (TVC)
Heterotrophic Plate Count (HPC)
Purpose: Measures the total number of viable bacteria present in a water sample. It does not identify specific bacteria or indicate whether they are harmful.
Common uses:
Drinking water quality monitoring
Process water testing
Cooling towers
Hospital water systems
Food and beverage industries
Typical method:
Plate Count Agar (PCA) or similar media
Incubation at specified temperatures (commonly 22°C and/or 36–37°C) for defined periods
Results reported as CFU/mL (Colony Forming Units per milliliter)
Interpretation:
Low counts generally indicate good microbiological quality.
High counts may suggest poor sanitation, biofilm formation, or stagnation, but they do not necessarily indicate the presence of pathogens.
2. Legionella Testing
Purpose: Detects and quantifies bacteria of the genus Legionella, particularly Legionella pneumophila, which can cause Legionnaires’ disease.
Common sources tested:
Cooling towers
Hot and cold water systems
Hospitals
Hotels
Spa pools
Decorative fountains
Testing methods:
Method
Detects
Time to Result
Culture (ISO 11731)
Live Legionella
7–10 days
qPCR
Legionella DNA
Few hours to 1 day
Rapid antigen tests
Specific targets
Minutes to hours (limited use)
Results:
Reported as CFU/L for culture methods.
qPCR results are typically reported as genome copies per liter or similar molecular units, depending on the laboratory.
Comparison
Feature
TBC
Legionella
Measures
Total viable bacteria
Specific Legionella bacteria
Specificity
Non-specific
Highly specific
Indicates pathogens?
No
Yes
Typical unit
CFU/mL
CFU/L
Main purpose
General water hygiene
Public health risk assessment
Why both tests are often performed
A water system can have:
Low TBC but detectable Legionella, or
High TBC but no Legionella.
Because of this, TBC cannot be used to confirm or rule out the presence of Legionella. For systems with a risk of aerosol generation (such as cooling towers, healthcare facilities, hotels, and large building water systems), Legionella testing should be performed separately as part of a water safety management program.
If you’re working with a particular standard (such as ISO, WHO guidance, ASHRAE, or local regulations), the testing frequency and action limits may differ. I can also explain the relevant requirements for those standards.
Interested in Learning more about water testing, Visit our dedicated water testing services page: WATER TESTING
We are currently bidding for a new project “ CONSTRUCTION SERVICES FOR WATER SUPPLY TO SIR BANI YAS ISLAND IN WESTERN REGION“ and invite your esteemed company to submit your techno-commercial quotation for the attached “PIPE HYDROSTATIC TESTING”. Please find below the attached RFQ document for your kind review.
We kindly request you to submit your best competitive offer on or before 22ND JULY 2026. Your prompt response and support in expediting this process will be highly appreciated. if any query you can contact the undersigned through telecon Mob :______ email. In case any Scope of Work falls outside your scope of services, you may exclude the same and submit your proposal for the relevant scope only.
Please acknowledge the receipt of the documents and confirm expression to quote by return mail by today.
Project details:
Tender Project Name – CONSTRUCTION SERVICES FOR WATER SUPPLY TO SIR BANI YAS ISLAND IN WESTERN REGION
Client – ______
Project Duration – 24 months
Project Location – Jabel Dhanna, Abu Dhabi
Project Scope of Work
The scope of work entails the infrastructure Works package for Pipeline works
Attachment :
BOQ
Terms & condition
Key Commercial Terms:
1
Type of Contract
HYDROSTATIC TESTING
2
Scope of Work
“PIPE HYDROSTATIC TESTING” as per the attached BOQ, Specification and Drawings
3
Delivery/ Completion Time Period
The work shall start as per the mutually agreed schedule during the finalization of the contract.
4
Price Terms
The price shall include all cost including as mentioned in the Technical specification.
5
Performance Bond
Performance Bank Guarantee for 10% of Contract value to be submitted. Refer the detailed “Subcontract terms & condition” enclosed.
6
Payment terms
Payment shall be made within 60 days from the payment certificate after recovering the advance if any. If any Advance Payment required , Max 10% against advance Bank Guarantee
7
Escalation
Firm & Fixed for the contract period
8
Retention money
10% retention will be deducted from each bill.
9
Defect Liability period
12 months from the date of successful completion of the project.
10
Liquidated Damages
In case job is not completed as per schedule agreed, LD will be applicable as 1% of order value per week, up to max 10% of order value.
11
Validity of Offer
Offer shall minimum valid for 120 days from the date of offer
12
Insurance
In Seller Scope. Refer the attached “Subcontract Agreement” enclosed.
13
Taxes & Duties
As per UAE tax law
14
Compliance
As per company
One of our highly proficient and ISO certified laboratory would be taking over this job.
Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].