Environmental Testing in Malta, Europe

Enquiry:

We often have jobs requiring monitoring of land, waste, groundwater and air, where we take the samples and send them to an ISO 17025-certified lab for analysis.  A list of a typical analytical suit is detailed on the below tables:

Bulk testing:

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
Total petroleum hydrocarbons: C10-C40GC-FIDIn-house method0.1 – 10 mg/kgYes (soil)
Total Organic CarbonTitrationIn-house method based on BS 1377<0.1%Yes (Soil)
BTEXGC-MS (Headspace)In-house method based on EPA Method 8260, Revision B<1 μg/kgYes (Soil)
PAHsGC-MSIn-house method based on EPA Method 8270, Revision C0.01 ug/kgYes (Soil)
PCBsGC-MSIn-house method based on EPA Method 8082;
EPA Method 1668
7 μg/kgYes (Soil)
MetalsICP-OESIn-house method based on BS 1377All <1 mg/kg    Yes (Soil)
TBTGC-MSIn-house method0.01 mg/kgNo
AsbestosPolarised light microscopyHSG248Presence / absence; if asbestos is detected the quantification test has a LoD of 0.001%Yes
MoistureGravimetryn/a0.1%No

Waste characterisation testing

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
Acid neutralising capacity
(pH 4, pH 7)
TitrationEA NEN 7371:2004(+/-) mol/kgNo
Loss on ignitionGravimetryIn-house method based on BS 1377:19900.01%No
pHProbeBS 1377No

Leachability testing

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
As (dissolved)ICP-OES (Filtered)In-house method based on BS 1377<1.0 µg/kgYes
Ba (dissolved)<0.05 µg/kg
Cd (dissolved)<0.1 µg/kg
Cr (dissolved)<0.4 µg/kg
Cu (dissolved)<0.3 µg/kg
Hg (dissolved)<0.5 µg/kg
Mo (dissolved)<0.4 µg/kg
Ni (dissolved)<0.3 µg/kg
Pb (dissolved)<1 µg/kg
Sb (dissolved)<1.7 µg/kg
Se (dissolved)<4 µg/kg
Zn (dissolved)<0.4 µg/kg
Total dissolved solidsGravimetryIn house method based on PN-EN 27888:19994 mg/LYes
Phenols (total-mono)ColorimetryIn house method10 µg/LYes
Dissolved organic carbonTOC Analysern/a0.1 mg/LNo
ChlorideDiscrete analyserIn house method0.15 mg/LYes
FluorideDiscrete analyserIn house method0.05 mg/LYes
SulphateDiscrete analyserIn-house method0.03 mg/LYes

Could you kindly let us know if you are able to provide some or all of the attached analytical services, and send us a copy of your ISO 17025 / test-specific certification if so?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Testing Annual Contract, Doha Qatar

Enquiry:

Kindly share with us your best AMC Proposal to our hotel according to the below scope of work:

SL No.Water testQuantity (samples)Tests RequiredDurationSamples per Year
1Legionella Analysis14 Quarterly456
2Pseudomonas Analysis5 Monthly1260
3Chilled Water System2Turbidity,ph,conductivity-TDS-TSS-T,Hardness,Total Alkalinity,Chloride,Total Iron-Copper-NitriteMonthly1224
4Total Bacteria Count10 Monthly12120
5E coli15 Monthly12180
6Heterotrophic Plate9 Monthly12108
7Fecal Coliform9 Monthly12108
8Domestic Water Chemical Analysis10Turbidity,ph,conductivity-TDS-TSS-T,Hardness,Total Alkalinity,Chloride,Total Iron-Copper-NitriteMonthly12120

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

STP Water Testing in KSA

Enquiry:

please give us your best offer for the analysis of 1 STP water sample with the following analysis. BOD, TSS, Turbidity, Ammonia, NH3, and Copper, CU. We appreciate for a prompt response of this query.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Liquid Nitrogen Testing in Singapore

Enquiry:

We would also like to take sample of Liquid Nitrogen from tanker for external lab analysis.

Would you also able to provide us a quote for this LIN analysis?

The location is at Jurong Island.

The parameters that we would like to analyse are:

  1. Coliform
  2. Staphylococcus aureus
  3. Total Bacteria Count
  4. Yeast & Mould Count
  5. Enterobacteriaceae
  6. Escherichia coli
  7. Salmonella
  8. Listeria monocytogenes
  9. Clostridium Botulinum
  10. Oil Mist
  11. Nitrogen Oxide
  12. Nitrogen Dioxide
  13. Carbon Monoxide
  14. Total Hydrocarbon (as Methane)
  15. Oxygen Content
  16. Moisture Content
  17. Wood, Metal & Glass Particles
  18. Total Particle Count     
  19. Heavy metal such as:

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Soil, Mix Concrete, and Water Test in Saudi

Enquiry:

We start to build the dates factory and need your lab service to test the soil, mix concrete and water with following Parameters.

  1. Trial Test pit for Soil        
  2. Plate bearing (Dry condition) (ASTM) 2-test
  3. Attain the trial mix + Air content + Slump test + Temperature + Unit weight.
  4. Setting time of concrete (Initial and Final)
  5. ISAT
  6. RCP (ASTM)
  7. Water Absorption – Hardened concrete
  8. Water Permeably (BS EN)

Please send your best possible offer for the above.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Hydraulic Oil Inspection in Dubai

Enquiry:

I was looking for an oil inspection lab in Dubai and found your company.

I would like to inspect the hydraulic oil used in our cylinder, can you please send the tariff price for oil inspection.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].