• Home
  • Archive by category "Air Quality Test"

Indoor Environmental Monitoring in Al Ain, UAE

Enquiry:

We would like to request a quotation for conducting the Indoor Air, Indoor Noise, Lux & Ambient Air Quality Monitoring services at our facility.

Kindly provide your detailed proposal, including scope of work, methodology, timeline, and commercial terms at your earliest convenience.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Ambient Air, Stack Emission Testing in RAK, UAE

Enquiry:

We would also like to incorporate the following detailed testing and documentation for our submission to the RAK Government:

1. **Stack Emission Testing**

We require testing to be conducted on the main exhaust stacks, specifically before and after the filtration system. The parameters to be measured, using accredited laboratory methods (such as USEPA/EN standards), should include:

* Total Volatile Organic Compounds (TVOCs)

* Formaldehyde, Acetaldehyde

* SO₂, NOx, HCl, Cl₂

* Particulate Matter (PM₁₀ / PM₂.₅)

* Odor Concentration (OU/m³) – utilizing Dynamic Olfactometry (EN 13725)

The expected outcome for this testing is to demonstrate a clear reduction (≥ 80%) in odor-causing gases and particulates after the filtration system.

2. **Ambient Air Monitoring (Fenceline Study)**

For this, we request the placement of monitoring stations both upwind and downwind of our facility boundary. The monitoring period should be for 72 continuous hours, and the parameters to be measured include:

* TVOCs

* SO₂, NOx

* PM₂.₅ / PM₁₀

* Odor concentration

The expected outcome is to show no significant difference between downwind and upwind concentrations, thereby confirming effective odor control.

3. **Filtration System Performance Test**

We require measurements of pollutant concentrations at both the filter inlet and filter outlet to calculate the filtration efficiency (%) for each pollutant. The expected outcome is to document an efficiency of > 85% across key pollutants.

4. **Root Cause and Corrective Action Documentation**

We need documentation that addresses the root cause of odor emissions, which we’ve identified as being linked to VOCs and particulates during specific production stages. The corrective action taken is the installation of a multi-stage purification system (comprising pre-filters, ultraSORB chemical filters, and final filters). Additionally, preventive measures such as a scheduled maintenance and filter replacement plan, along with routine stack and ambient monitoring every 6 months, should be included.

5. **Deliverables for EPDA**

The final deliverables for submission to EPDA should include:

* Laboratory reports with before/after results.

* Graphs and tables clearly showing emission reductions.

* Photographs of the installed system and the monitoring setup.

* A comprehensive monitoring and compliance plan for ongoing reporting.

Could you please confirm if your company is recognized by the Ras Al Khaimah government/Municipality for these additional tests and provide an updated quote that incorporates these expanded requirements, including details on the cost and any other formalities? We are still aiming to schedule this as immediately as possible.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Tank Calibration, Indoor, Outdoor Air Quality Test, UAE

Enquiry:

Please quote the best competitive price for the below

      1. INDORE & OUTDOOR AIR QUALITY & NOISE LEVEL TEST    -     1 Nos

      2. DIESEL TANK INSPECTION AND CERTIFICATION(19000 GL)     -     1 Nos


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Air and Water Quality Testing in Riyadh, KSA

Enquiry:

We are seeking air and water quality testing services in Riyadh, Saudi Arabia, and would like to request a formal quotation for the same.

Kindly find below our specific laboratory requirements:

  1. Laboratory Accreditations:
    The laboratory must hold valid ISO/IEC 17025 accreditation issued by an ILAC MRA member body. The relevant test methods and parameters should be clearly highlighted in the laboratory’s scope of accreditation.
  2. Test Methodologies:
    Please ensure that the test methodologies used for the analysis of the listed parameters are clearly stated in both the quotation and the final report.
  3. Chain of Custody:
    A proper chain of custody must be maintained and provided for all analyzed parameters.
  4. Sample Collection Support:
    Kindly confirm whether your lab provides onsite sampling or sample collection support as part of your services.

We have attached the list of required parameters along with their threshold limits and sample types for your reference. We request you to review the same and share your detailed quotation accordingly.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Shelf Life, Air Quality, Swabs Testing in UAE

Enquiry:

Please share a quotation for the following / reference guidelines as per any GSO Standard or local authority

  1. Shelf Life Analysis of the following in 30 days 60 days and 90 days

Ground Coffee

Ground Cardamom

  1. Quality of Air Micro and Chemical
  2. Hand Swab
  3. Surface Swab

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Noise, Air, and Emission Testing in Sri Lanka

Enquiry:

We are requesting to provide us with quotations for the below requirement

Requirement; BOUNDARY NOISE MEASUREMENTS (Day and Night Time) STACK EMISSION MEASUREMNTS (03 Boilers, LPG) STACK EMISSION MEASUREMNTS (Diesel Generator) AMBIENT AIR QUALITY OCCUPATIONAL EXPOSURE MONITORING (Lux, Noice, Temperature, Heat stress, Dust) (Inside) More infrormation please contact Mr Dasun 9470 6223 550

Kindly make sure you response to this request on/before Tomorrow before 5pm

if you have any further concern or clarification, please be free to contact me.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].