• Home
  • Archive by category "Gas Analysis"

Sampling, Analysis of Pressurized Process Fluid Gas Stream in Iraq

Enquiry:

Sampling and Analysis of Pressurised Process Fluid (Gas Stream) from Upstream Air cooler

Qty: 1 CYLINDER.

1. Purpose

The purpose of this Scope of Work is to investigate the process fluid upstream of Air Cooler to determine the presence and quantity of water in the stream and evaluate its potential contribution to corrosion and deposition issues. The investigation will also confirm the presence of elemental sulfur and all spectrum composition, quantify and characterize any solids present, and provide information to support equipment integrity assessment and future mitigation actions.

2. Objective

The external laboratory is requested to perform a detailed analysis to

determine:

• Determine the water vapour content of the overhead gas upstream of Air Cooler using ASTM D5454 or an equivalent validated method. Report the result in ppmv and mg/Sm³ or lb/MMscf, as applicable.

• Determine whether elemental sulfur and all spectrum elemental present in the process fluid.

• Determine process gas composition using Gas Chromatography. to support phase behavior modelling and identification of potential hydrocarbon and water condensation locations between the Stabilizer Overhead tower until Downstream cooler.

• Determine or calculate the water dew-point temperature at the actual operating pressure and at agreed reference pressures. The basis, method, software or equation used shall be stated in the report.

• Quantify and characterize any suspended solids. using XRD method.

Determine total

particulate / solids loading in the process gas using a validated filtration (Example pore

0.45 or 1 micron) and gravimetric method. Report results in mg/m³.

• Identify the chemical composition and structure of the solids.

3. Sample Information

• Sample Type: Pressurized process fluid sample (gas stream).

• Source Location: Upstream of Air Cooler • Facility: PF-1 Stabilizer System • Special Requirement: Sample shall be collected under pressure and protected from air exposure during sampling, transportation, and laboratory handling to prevent oxidation and sulfur formation.

4. Required Laboratory Tests

4.1 Fluid Characterization

• Water content determination.

• Visual inspection for solids and sulfur deposition.

• Confirmation of elemental sulfur presence, if any.

4.2 Solids Analysis

If solids are present:

• Total solids quantification.

• Chemical composition analysis.

• Structural/mineralogical analysis using suitable analytical techniques such as XRD, SEM-EDS, FTIR, or equivalent.

• Identification of corrosion products, sulfur species, salts, and other inorganic compounds.

5. Reporting Requirements

The final laboratory report should include:

• Water content results.

• Confirmation of elemental sulfur presence or absence.

• Quantity of solids identified.

• Detailed chemical and structural characterization of solids.

• Interpretation of solids formation mechanism.

• Raw data + interpreted results in PDF and Excel formats

1. Timeline & Deliverables

• Turnaround Time: 2 – 4 weeks starting from sample submission.

• Deliverables:

• Full analysis report (PDF)

▪ Raw analytical data (Excel)

▪ Any supporting images (FTIR, XRD patterns)

2. Third-Party Laboratory Requirements

• The laboratory shall:

▪ ISO 17025 accreditation. The third-party laboratory shall be accredited to ISO/IEC 17025 for the applicable analytical methods. Where a required analysis is outside the laboratory’s accredited scope, this shall be clearly declared in the technical proposal and final report.

▪ Review the scope and analytical requirements.

▪ Lab shall provide a detailed description of the analytical procedures or reference to Standards and analytical schedule for review ▪ Lab shall also communicate to the minimum required sample volumes / quantity.

3. Reporting

• Final report including:

o Executive summary.

o Detailed findings per sample.

o Tables, graphs, and chromatograms


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Flue Gas Testing and Generator Emission Monitoring in Sri Lanka

Enquiry:

Could you please provide a formal quotation for Stack Emissions and Flue Gas Monitoring at our facility?

Emission Sources:

  – Boilers: 3 units
  – Generator: 1 unit

Required Testing Parameters:

  – O2, CO2, CO, SO2, NO, NO2, NOx, PM
  – Flue Gas Temperature, Excess Air, Combustion Efficiency

The final testing reports are required for CEA/EPL compliance and international audits. Please ensure that standard limit comparisons are included in the report and that all transport costs are factored into the quotation.

For reference, our facility location is:

Due to our audit schedule, the testing must be conducted and the final certified report issued on or before September 17, 2026. Please send your quotation and estimated turnaround time at your earliest convenience.

If you require any additional technical details, please let me know.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

N2 Gas Mixture Analysis in Dammam, KSA

Enquiry:

To ensure our product quality and complete the required validation process, we need to analyze the mixture listed below. Kindly provide your quotation for the same.

Additionally, please share the instrument specifications suitable for analyzing this mixture, along with the calibration certificate, measurement accuracy, and expected reliability of the test results.

S.NoComponentCylinderValvePressure
1HCL : 2.5 ppm in N250Ltr AlumCGA-660 SS150 Bar

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

LPG Gas Testing in Batangas, Philippines

Enquiry:
Our Company is looking for LPG testing centers that caters quality testing of LPG in terms of:

1. Composition (Propane:Butane ratio)

2. Contaminants (Hydrocarbons)

3. Physical Properties

4. Combustion Performance


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Hydrocarbon, Solid, qPCR, DNA Sequencing Test in Kuwait

Enquiry:

We are currently seeking a specialized laboratory to support an ongoing project in Kuwait. The required laboratory services include below categories:

  1. Product (Hydrocarbon) analysis 
  2. Solid analysis 
  3. qPCR and DNA sequencing 

Please refer to the detail testing requirement in the attached excel spreadsheet. 

Please note that, the sample collection will be done by our team only in Kuwait, and we shall courier/handover the sample to your kind office. Please also let us know, if you prefer to collect the sample from our team present in Kuwait. If yes, then please include the charges for the same.

We look forward to your prompt response and the best price in the attached format.

Quotation Required for Lab Testing for Oil & Gas Sample
Sl. No.Test TypeTest IncludesTest DescriptionQty.RateAmount
1Product AnalysisLiquid Hydrocarbon Analysiscomplete liquid/gaseous hydrocarbon analysis including dissolved acid gases (CO2, H2S), TAN, and sulfur compound etc3                                 –  
2Gaseous Hydrocarbon Analysis4                                 –  
3Solid AnalysisDeposit Characterization TestsParticle size analysis, XRD, SEM, SEE etc. Deposits may contain iron compounds (oxides, sulfides, carbonates, hydroxides), silica, silicates, and oil residues as major components.7                                 –  
4Deposit Composition                                 –  
5Particle Size DistributionThe particle size analysis shall give weight fraction of the deposit having various particle size ranges, for example: 1-10 µm, 10-100 µm, 100-1000 µm, 1000-10000 µm, >10000 µm                                 –  
6DNA Sequencing AnalysisDNA SequencingBacteria culture and identification of bacteria species. The DNA sequencing of the bacteria present in the sample should characterize different strains coming under the categories of GAB (General Aerobic Bacteria), GAnB (General Anaerobic Bacteria), and SRB (Sulfate Reducing Bacteria). The analysis shall include quantitative estimation of the level of bacteria infestation, for example: counts/gram in the sample7                                 –  
7qPCR                                 –  

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Natural Gas Compositional Analysis C11+, BTX in Pakistan

Enquiry:

We would like to request a quotation for the following laboratory analysis services for a natural gas sample (Sale Gas),

  1. Natural Gas Compositional Analysis up to C11+, including BTX.
  2. Moisture Content Analysis.

Kindly provide the following information in your quotation,

  • Testing method/standard to be used.
  • Turnaround time for analysis and reporting.
  • Commercial quotation, including all applicable charges.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Gas Purity Testing in UAQ, Dubai, Port Khalifa, UAE

Enquiry:

Please quote urgently for the below mentioned services at our 3 shipyard places.

  1. Gas purity testing & issuing analysis report at Dubai Maritime City
  2. Gas purity testing & issuing analysis report at Umm Al Quwain
  3. Gas purity testing & issuing analysis report at Port Khalifa, Abu Dhabi

We will be also required solution from gas supplier company, kindly guide us.

•         Gas Purity Certificate (Batch-wise / Rack-wise)

•         Cylinder Test Certificates

•         SDS / MSDS for the gases supplied

•         Pressure / Leak Test Reports

•         Rack Calibration Certificates

•         Pressure Gauge Calibration Certificates

Kindly also advise if any flow meter instrument for the supply quantity checking.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Raw Gas Co2 Testing in Pakistan

Enquiry:

I am writing to inquire whether your company provides detailed gas analysis services in Pakistan, specifically for CO₂ raw gas produced from a fermentation process. We are looking for comprehensive analysis covering gas composition, impurities, contaminants, and any other relevant parameters required for downstream processing and purification.

If this service is available, I would appreciate it if you could kindly share:

  • The scope of your gas analysis capabilities
  • Sample requirements and testing procedures
  • Lead time for results
  • Pricing and commercial terms
  • Any additional technical specifications or certificates you can provide

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Residual Gas Analysis for N2 on SMD, Indonesia

Enquiry:

We would like to request your quotation for residual gas analysis at the laboratory to determine the N2 gas content level in our material.
The total quantity to be analyzed is 8 cylinders of N2 gas.

We look forward to receiving your favorable quotation.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].