Test Kit for Lube Oil Quality Check in Fujairah, UAE

Enquiry:

Lube Oil Testing Kits required for Ajman and Fujairah.

Would you please advise your best price and availability of following items:-

NoItem CodeItem DescriptionQtyUnit
1000-0TEST KIT LUB OIL CHECK 5, FOR 5 DIFFERENT TESTS1BOX

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Purchase of Complete Lab Equipment in Kuwait

Enquiry:

We request your quotation for the Purchase of Laboratory equipment that complies with the following quantities and requirements as mentioned below: 

1 Ion Chromatography (IC) System UNIT 1 Description:As per the technical specifications attached in Appendix 1.1 Connections & Wiring Set 1 Description:As per the technical specifications attached in Appendix 1.2 Reservoir tray Unit 1 Description:As per the technical specifications attached in Appendix 1.3 Washing glass bottles Units 2 Description:As per the technical specifications attached in Appendix 1.4 Flow Channel selection Valve Unit 1 Description:As per the technical specifications attached in Appendix 1.5 Vials (for Auto Sampler) Units 100 Description:As per the technical specifications attached in Appendix 1.6 On-site installation Package 1.7 On-site training Package 2 Ultraviolet-Visible (UV-Vis) Spectrophotometer UNIT 1 Description:As per the technical specifications attached in Appendix 2.1 On-site installation Package 2.2 On-site training Package 3 Drop Test Machine UNIT 1 Description:As per the technical specifications attached in Appendix 3.1 On-site installation Package 3.2 On-site training Package 4 Impact Test Machine UNIT 1 Description:As per the technical specifications attached in Appendix 4.1 On-site installation Package 4.2 On-site training Package 5 Inductively Coupled Plasma Mass Spectrometry (ICP-MS) UNIT 1 Description:As per the technical specifications attached in Appendix 5.1 High-Purity Argon Cylinder:-Nominal cylinder water capacity: 40L Purity ≥ 99.999% suitable for ICP-MS use. UNIT 3 5.2 Compatible high-purity pressure regulator (two-stage): Suitable for ≥ 99.999% argon service. UNIT 1 5.3 High-Purity Helium Cylinder:-Nominal cylinder water capacity: 40L-Purity ≥ 99.999% suitable for ICP-MS use. Compatible high-purity pressure regulator (two-stage) suitable for ≥ 99.999% helium service. UNIT 1 5.4 On-site installation Package 5.5 On-site training Package LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 SALMA [email protected] R&E Petroleum Equipments Company Purchase of Laboratory equipment REF# DATE : Attention : Prepared By: Email subject 7892 30/08/2025 6.1 Capillary Column used in Gas Chromatography (GC) system: UNIT 1 Description:As per the technical specifications attached in Appendix 6.2 Certified Internal Standards for GC-MS: •Compatible with existing Gas Chromatography-Mass Spectrometry (GC-MS) system, model Agilent Technologies 6890N. •All internal standards shall be certified reference materials, traceable to internationally recognized sources. •Each standard shall be supplied with a Certificate of Analysis (CoA) stating the concentration or purity, solvent/matrix, lot/batch number, and expiration date. Quantities referred below 6.a) Butyltin (d₉) g 250 6.b) Tributyltin (d₂₇) g 250 6.C) Tetrabutyltin (d₃₆) g 250 6.d) Triphenyltin (d₁₅) g 250 6.3 Reagents for GC-MS: •Compatible with existing Gas Chromatography-Mass Spectrometry (GC-MS) system, model Agilent Technologies 6890N. •All reagents shall be of analytical grade or higher (≥98% purity). •Each reagent shall be supplied with a Certificate of Analysis (CoA) indicating purity, lot/batch number, and expiration date. Quantities referred below 3.a) Sodium tetraethyl borate (NaB(C2H5)4) g 250 3.b) Methyl trichlorotin (CH₃SnCl₃) Liter 1 3.c) Dimethyltin(II) chloride ((CH₃)₂SnCl₂) Liter 1 3.d) Tri-n-butyltin(IV) chloride (C₄H₉SnCl₃) g 250 3.e) Di-n-butyltin(II) chloride ((C₄H₉)₂SnCl₂) g 250 3.f) Tri-n-butylstannane chloride ((C₄H₉)₃SnCl) Liter 1 3.g) Tetra-n-butylstannane ((C₄H₉)₄Sn) Liter 1 3.h) Octyltrichlorotin (C₈H₁₇SnCl₃) Liter 1 3.i) Di-n-octyltin(II) chloride ((C₈H₁₇)₂SnCl₂) Liter 1 3.j) Di-n-propyltin(II) chloride ((C₃H₇)₂SnCl₂) Liter 1 3.k) Diphenyltin(II) chloride ((C₆H₅)₂SnCl₂) Liter 1 3.l) Triphenyltin(IV) chloride ((C₆H₅)₃SnCl) Liter 1 3.m) Tri-n-butyltin(IV) chloride ((C₄H₉)₃SnCl) d₂₇ Liter 1 3.n) Tetra-n-butyltin(IV) ((C₄H₉)₄Sn) d₃₆ Liter 1 3.o) Butyltrichlorotin (C₄H₉SnCl₃) d₉ Liter 1 3.p) Triphenyltin(IV) chloride ((C₆H₅)₃SnCl) d₁₅ Liter 1 3.q) Tetrahydrofuran (C₄H₈O) Liter 1 3.r) Sodium chloride (NaCl) Liter 1 3.s) Dichloromethane (CH₂Cl₂) Liter 1 3.t) Tri-n-butyltin(IV) chloride (C₄H₉SnCl₃) Liter 1 6.4 Supplies for installation and operation of Capillary Column •The following supplies shall be provided for installation and operation of the capillary column and associated components of the Agilent Technologies 6890N GC system with mass spectrometry detector. •All parts must be fully compatible with the Agilent Technologies 6890N GC system and its associated MS detector. Quantities referred below 4.a) O-ring compatible with GC inlet system Units 2 4.b) Inlet Nut (upper assembly) compatible with GC inlet Units 2 4.c) Ferrule for Flame Ionization Detector (FID) connection compatible with capillary column Unit 1 4.d) High-vacuum Pump oil compatible with installed GC-MS vacuum pump Units 2 4.e) Column inlet nut compatible with GC inlet fittings Units 2 4.f) Electron Ionization (EI) Filament compatible with installed Mass Selective Detector (MSD) ion source Units 2 Lot 6: Equipment Parts and Consumables for Gas Chromatography & Mass Spectrometer (GC-MS) System – compatible with Agilent Technologies 6890 N Gas Chromatography (GC) and Associated Mass Spectrometer (MS) 6.5 Computer System and Software:-A compatible PC & monitor (or laptop) as well as a printer shall be included.-The PC shall be pre-installed with all necessary software required for instrument control, data acquisition, processing, analysis and report generation.-Software licenses, drivers and any necessary activation keys must be included. Licenses shall be perpetual (non-expiring) where available. If the supplier only offers subscription-based licensing, a minimum subscription duration of three (3) years is required, with all renewal costs clearly indicated in the proposal. All licenses must include software updates and technical support during the license period.-The system shall be fully operational upon delivery, requiring no additional software installation. Unit 1 6.6 On-site installation Package 6.7 On-site training Package 7.1 High Performance Liquid Chromatography (HPLC) Column: •Compatible with the Waters 2695 High Performance Liquid Chromatography (HPLC) system •Material: Stainless steel •Dimensions: 250 mm length and 4.6 mm internal diameter •Packing material: Spherical silica gel coated with octadecylsilane (C18), with particle size 5 µm Unit 1 Description:As per the technical specifications attached in Appendix 7.2 Ultraviolet (UV) Detector Lamp: •Compatible with Waters 2487 UV Detector Unit 1 7.3 Battery for Ultraviolet (UV) Detector: •Compatible with Waters 2487 UV Detector Unit 1 7.4 Analytical Standards for High Performance Liquid Chromatography (HPLC): •All standards shall be of analytical grade, with a purity of ≥ 99% •Each standard shall be supplied with a Certificate of Analysis (CoA), stating the purity, lot/batch number, and expiration Quantities referred below 4.a) · 2,2-Bis(4-hydroxyphenyl)propane (Bisphenol A) g 250 4.b) · 4,4′-(Methylethylidene)bisphenol g 250 7.5 Computer System and Software: •A compatible PC & monitor (or laptop) as well as a printer shall be included. •The PC shall be pre-installed with all necessary software required for instrument control, data acquisition, processing, analysis and report generation. •Software licenses, drivers and any necessary activation keys must be included. Licenses shall be perpetual (non-expiring) where available. If the supplier only offers subscription-based licensing, a minimum subscription duration of three (3) years is required, with all renewal costs clearly indicated in the proposal. All licenses must include software updates and technical support during the license period. •The system shall be fully operational upon delivery, requiring no additional software installation. Unit 1 7.6 On-site installation Package 7.7 On-site training Package Note: – I NEED THE COST OF TRAINING & INSTALLATION -Currency of Quotation: USD- I NEED THE TOTAL WEIGHT OF ITEMS- I NEED the Country of Origin Lot 7: Equipment Parts and Consumables for High-Performance Liquid Chromatography (HPLC) – compatible with Waters 2695 High Performance Liquid Chromatography (HPLC)


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Double Cap Oil Sampling Bottles in Dubai, UAE

Enquiry:

Kindly quote for the inquiry attached at your earliest convenience.

Pos.Item Name / DescriptionItem NumberQuantityUOM
3.01000 ml Plastic Lab Bottle Sample with Double Cap Bottle sample for Lub Oil and Grease sample Analysis. Bottle sample for Lub Oil and Grease sample Analysis. 50.00PCE
4.0250 ml Plastic Lab Bottle Sample with Double Cap 50.00PCE

Remark:

Consumable of bottle sample for lube oil, fluid analysis & bunker sample as well.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Vessel Engine Room Flowmeter in Abu Dhabi, UAE

Enquiry:

I am writing on behalf of Logistics, a provider of marine services to the onshore and offshore Oil & Gas, commercial shipping, and maritime industries.

Please find the attached outlining our requirements. We kindly request you to provide your most competitive quote based on the following terms:

Vessel: ____________

Important Note: When preparing your quotation, please specify clearly whether you are proposing:

  • The exact item requested as per the specifications provided in the attachment.
  • An alternative/replacement item, detailing any differences from the requested item.
  • A superseded/upgraded version, providing full specifications and benefits of the suggested alternative.

Should you have any questions or require further clarification, please do not hesitate to contact me.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube Oil Test Kit and Datasheet in Dubai, UAE

Enquiry:

I would like to get best price quote for the following item mentioned below:

L.O Test Kit (TBN, Viscosity, Water in Oil %, … etc.) – 2sets

Please provide the quotation with lead-time and data sheet.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Laboratory Design, Equipment, and Furniture Setup in Oman

Enquiry:

We are in the process of developing a large-scale shrimp project in Oman for local and international markets.

Aquatic Investments Excellence LLC is a JV based in Muscat owned by GTR Royal trading (D42, Dubai) 61% and Fisheries Development Oman 39% (FDO, Oman) to develop a large-scale shrimp farming operation in Sultanate of Oman. The project site is located at Al Jazer, Al Wusta Governorate, 750KM south of Muscat, and 200Km south of Duqm on the coast of Arabian sea covering an estimated area of approximately 8600 hacters. After full  commissioning we will be harvesting 220,000 M.ton of P.Vannamei Shrimps each year.

For the above project we are excited to invite bio-test laboratory vendors to submit a proposal for the design, supply and commission of a state-of-the-art laboratory for Aquatic Investments Excellence LLC at Al-Jazir, 200KM South of DUQM. We are looking for a comprehensive solution that includes both the layout design, the necessary laboratory equipment & supplies and commissioning of Bio Laboratory.

Project Overview:

  • Scope: The design of a fully functional laboratory space, inclusive of layout planning, furniture, equipment, and specialized supplies tailored to our specific needs, our list of tests against the sample required in laboratory can be found in attachment.
  • Objective: To create a modern, efficient, and safety-compliant laboratory environment for routine checks of water, shrimps and environment parameters.

Requirements:

  • Detailed layout and floor plan of the proposed laboratory space.
  • Specifications and recommendations for the laboratory furniture, equipment, and supplies.
  • Installation and setup of all lab equipment.
  • Compliance with relevant health, safety, and environmental regulations.
  • Commissioning of the Laboratory.
  • After-sales support and maintenance services.

We would appreciate it if you could submit your proposal by 10 February 2025, which includes:

  1. A detailed approach to the project.
  2. A breakdown of costs, including design, supply & installation, and commissioning.
  3. A timeline for completion.
  4. Previous experience in similar projects or relevant case studies.
  5. Any other supporting documents or information relevant to our requirement.

Please feel free to reach out if you have any questions or need further clarification.

We look forward to reviewing your proposal and working with you on this exciting project.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Nitrogen Gas Purity Testers in Muscat, Oman

Enquiry:

I hope this email finds you well, we are kindly request you to provide the best lowest price for the following urgently.

Sr NoDescriptionUOMQty
1PURITY TESTER, NITROGEN GAS, P/N RTI 3558002200, BRAND: NITROPRO, MAKE: RTIEA11

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].