• Home
  • Archive by category "Lube Oil Analysis"

Lube and Transformer Oil Testing Contract in Iraq

Enquiry:

TEPRH is hereby inviting you to this Request for Information (RFI) related to provision of Lubricant Oil Analysis.

We want to know if you’re capable of providing attached scope of work services for our operations in Iraq :

  1. Supplier to confirm if it can deliver attached requirements? If supplier can only provide partial of the scope, please advise specifically which part of the scope it can provide;
  2. Supplier shall clearly specify whether the services can be provided in preferably Basra, other locations in Iraq or in Middle East;
  3. Supplier shall provide previous experience relevant to the subject scope of services;
  4. Any prior experience providing services to TEPRH.

APPLICABLE STANDARDS
Testing shall be conducted in accordance with the latest edition of applicable standards
including but not limited to:
IEC 60599
IEC 60156
IEC 60422
IEC 60814
IEC 62021
IEC 60247
IEEE C57.104
ASTM D1816
ASTM D1533
ASTM D971
ASTM D445
ASTM D2896
ASTM D664
ASTM D6304
ASTM E2412
ASTM D7593
ISO 4406
ISO 17025 – Guidance for interpreting dissolved gas analysis (DGA) – Determining the dielectric breakdown voltage of insulating liquids at
power frequency – Supervision and maintenance guide for insulating oils – Water content determination in insulating liquids – Determination of acidity in insulating liquids – Insulating liquids permittivity dielectric factor – Guide for the interpretation of gases generated in mineral oil – Standard test method for dielectric breakdown voltage – Standard test method for water in insulating liquid – Standard test method for interfacial tension – Standard test method for kinematic viscosity – Standard test method for base number – Standard test method for acid number – Standard test method for determination of water – Condition monitoring of used lubricants using Fourier Transfer
Infrared (FTIR) – Fuel dilution for in-service engine oils – Cleanliness code chart & guide – Accredited laboratory requirement

  1. LABORATARY TESTING REQUIREMENTS
    Laboratory analysis in accordance with applicable standards in section.6, or equivalent
    international standards. The tests below are not intended to limit or restrict the scope of
    activities.
    7.1.
    Testing requirements of transformer oil
    The CONTRACTOR shall perform in accredited laboratory of applicable:
    7.1.1. Dissolved gas analysis (DGA)
    Perform DGA to evaluate incipient thermal and electrical faults within transformers.
    Analyse and report concentrations of:
    o Hydrogen (H2)
    o Methane (CH4)
    o Ethane (C2H6)
    o Ethylene (C2H4)
    o Acetylene (C2H2)
    o Carbon Monoxide (CO)
    o Cabon Dioxide (CO2)
    o Oxygen (O2)
    o Nitrogen (N2)
    Provide fault interpretation using methods such as:
    o IEC 60599
    o Duval triangle
    o Rogers ratio
    o IEEE C57.104
    7.1.2. Dielectric breakdown voltage (BDV)
    Determine the dielectric strength of transformer oil accordance with IEC 60156 or
    equivalent standards. The report shall include:
    o Individual test results
    o Average breakdown voltage
    o Acceptability assessment
    o Recommended corrective actions
    7.1.3. Moisture content analysis
    Determine the water content using Karl Fischer titration techniques and report:
    o Moisture content (ppm)
    o Saturation percentage
    o Impact on insulation performance
    7.1.4. Acidity test (TAN)
    Determine:
    o Total acid number (TAN)
    o Oxidation status of oil
    o Sludge formation tendency
    7.1.5. Interfacial tension (IFT)
    Measure and evaluate:
    o Oil contamination level
    o Oxidation by-products
    o Remaining oil condition
    7.1.6. Dielectric dissipation factor / Tan delta
    Determine:
    o Dielectric loss factor
    o Insulation deterioration
    o Presence of contaminants and aging products
    7.1.7. Furan analysis
    Perform analysis of furanic compounds to assess paper insulation degradation and
    estimate remaining insulation life.
    7.1.8. Oil physical properties
    Determine and report:
    o Appearance and color
    o Density
    o Flash point
    o Viscosity
    o Sediment and sludge content
    7.1.9. Conditional assessment and engineering evaluation
    The CONTRACTOR shall provide a comprehensive engineering assessment including
     Transformer health assessment, evaluating
     Oil condition
     Paper insulation condition
     Presence of thermal faults
     Presence of electrical discharges
     Presence of arcing faults
     Risk level of transformer operation
     Trend analysis with the historical records for
     Year to year comparison
     Trending graphs
     Fault development assessment
     Remaining service life indication
     Practical recommendations such as
     Continue in service
     Increased monitoring frequency
     Oil filtration
     Oil reclamation
     Oil replacement
     Transformer outage requirements
     Further diagnostic testing
    7.2.
    Testing requirements of Engine lubricating and Hydraulic oils
    The CONTRACTOR shall perform in accredited laboratory of applicable:
    7.2.1. Oil condition monitoring
    o Kinematic viscosity @40oC and 100oC
    o Viscosity index
    o Total base number (TBN)
    o Total acid number (TAN)
    o Oxidation
    o Nitration
    o Sulfation
    o Remaining additive package assessment
    7.2.2. Wear metal analysis
    Quantitative determination of wear metals including:
    o Iron (Fe)
    o Chromium (Cr)
    o Aluminum (Al)
    o Copper (Cu)
    o Lead (Pb)
    o Tin (Sn)
    o Nickle (Ni)
    o Silver (Ag)
    7.2.3. Contamination analysis
    o Silicon (dust ingress)
    o Sodium (Na)
    o Potassium (K)
    o Cooling water contamination indicators
    o Water content (Karl Fischer)
    o Fuel dilution
    o Glycol contamination
    o Particle contamination
    7.2.4. Cleanliness assessment
    o ISO4406 cleanliness code
    o Particle count analysis
    o Debris and ferrous wear particle analysis
    7.2.5. Advanced diagnostic tests – as and when required
    o FTIR spectroscopy – to identify organic and inorganic materials, characterising
    chemical functional groups, and detecting molecular structural changes in solids,
    liquids, and gases
    o Analytical Ferrography – to identify wear particles, their composition, and their
    origin by visually analysing them microscopically
    o Rotrode filter spectroscopy (RFS) – to detect large wear and contamination
    particles
    o Microscopic wear particle examination
    o Root cause failure investigation

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Central Chilled Water Plant Inspection, Testing in Khobar, KSA

Enquiry:

We are currently seeking a budgetary quotation for the subject requirement. Please find the attached Scope of Work (SOW) for your review.

Kindly note that the bid closing date and time is 22 September 2026 at 11:00 AM.

SOW:.

1. Purpose
The subcontractor shall perform a complete inspection, testing, and condition
assessment of the Central Chilled Water Plant (CWP) to evaluate the operational
condition of eight (8) water cooled Chillers, each having capacity of 1100 TR and
identify the extent of overhaul, repair, replacement, and maintenance activities
required to restore the plant to reliable and efficient operation.
2. Scope of Services
The subcontractor shall provide all necessary manpower, supervision, tools,
instruments, testing equipment, consumables, transportation, and documentation
required to execute the inspection.

2.1 Plant Survey and Data Collection

2.2 Chillers Inspection

  1. Testing Requirements
  2. Deliverables
    The subcontractor shall submit the following:
    4.1 Inspection Report
    4.2 Overhaul Recommendation Report
    4.3 Final Assessment Matrix
  1. HSE Requirements
  1. Exclusions
  1. Completion

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chillers Inspection and Oil Testing in Abu Dhabi, UAE

Enquiry:

We would like to invite your team to visit our buildings to inspect the existing chiller units and carry out the required oil viscosity testing.

Kindly arrange a site visit to assess the existing conditions and prepare your quotation for the testing and reporting services. The quotation will be submitted to Management for review and approval.

Scope of Work:

  • Inspect the existing chiller units at site.
  • Carry out the required chiller compressor oil viscosity test.
  • Provide the necessary testing and analysis.
  • Submit a detailed test report indicating the results, observations, and recommendations, if applicable.
  • The contractor shall provide all necessary manpower, tools, equipment, and testing instruments required to complete the works.

Important:
A site visit is required prior to submitting the quotation to verify the existing conditions, understand the scope of work, and ensure that the quotation accurately covers all required services.

For site inspection, kindly coordinate with below mentioned contact details.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lubricant Oil Testing as per SASO and GSO Specs in India

Enquiry:

We need testing of our Lubricant oil as per given testing standards , Kindly share quotes for the same.

GSO 1180:2021
SASO GSO ISO 4925:2024
GSO 1180:2021

SASO GSO 1785-2:2024 — Lubricating Oils for Internal Combustion Engines – Part 2: ACEA European Oil Sequences for Gasoline and Diesel Engines. This has been adopted as a mandatory Saudi standard.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Diesel and Lube Oil Testing in Riyadh, KSA

Enquiry:

We would like to clarify the following requirements regarding Diesel & Oil Testing.

Please review the below Scope of Work and confirm whether your laboratory can accommodate these requirements:

  1. Oil Analysis Testing for Generators – Qty: 12 samples
  2. Diesel Analysis Testing for Generators – Qty: 12 samples

Additionally, please confirm whether we can send the used oil samples in bottles for testing and whether your laboratory can process these samples and provide the relevant test reports.

We also require empty sample bottles with appropriate stickers/labels for the above quantities. Kindly confirm whether your team can arrange and provide the required bottles and stickers.

We will share a separate email with the detailed RFQ for your quotation and commercial offer.

Kindly confirm the above at your earliest convenience.

Scope of Work

Test Details Frequency
• Cetane Index to test the ignition quality of the diesel
• Water content test
• Contamination test of any dirt or rust
• Microbial contamination
• Viscosity test at 40°C
• Flash point test to check minimum temperature at which diesel vapor ignites
• Sulfur content test
• Density and API Gravity test
• Distillation range test for cold weather performance
• Lubricity testing
Diesel Testing
• Wear Monitoring /component wear levels (Fe, Cu, Pb etc)
• Contamination check (Water, fuel, soot, oxidation, etc)
• Oil Condition Check (Viscosity, additive levels, oxidation)
• Cleanliness Check – large particles, PQ Index
Oil Testing

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube Oil Testing in Baluchistan, Pakistan

Enquiry:

We require lab analysis of lubrication oil sample. Oil Type: SAE-30

You are requested to provide your quotation for the following test:

1. Physical Characteristics

  • Viscosity at 100°C (cSt)
  • Viscosity Index
  • Flash Point (Pass/Fail), °C
  • TBN (ASTM D2896), mg KOH/g

2. Wear Metals

  • Iron (Fe), ppm
  • Chromium (Cr), ppm
  • Tin (Sn), ppm
  • Lead (Pb), ppm
  • Copper (Cu), ppm
  • Nickel (Ni), ppm
  • Aluminium (Al), ppm

3. Contamination

  • Water Content (AquaTest), %
  • Sodium (Na), ppm
  • Silicon (Si), ppm

4. Oil Condition

Overall oil condition assessment.

Kindly provide your best quotation along with applicable testing Santander/methods and expected turnaround time for lab analysis report.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Vessel’s Water and Oils Testing in Ras Tanura, KSA

Enquiry:


Please send me your best quote for the following testing you can do at the Vessel

  1. Lube Oil
  2. Fuel Oil
  3. Diesel Oil
  4. Cooling Water
  5. Sewage Water
  6. Ballast Water
  7. Drinking Water

Also please quote whatever your company can do more.  Please do your immediate visit the site (Vessel) ASAP.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube Oil Testing in Kuwait

Enquiry:

SUBJECT:RFQ for Lub Oil Analysis (RFQ # ) 
END USER:Maintenance Department (Mechanical) 
You are kindly requested to forward us your Techno-commercial offer for the items in the below list along with complete technical specification and relevant Catalogues. 
Vocab #Long Description 
—Lube Oil Analysis for Chlorine Liquefaction Compressor Unit  
Note: The oil parameters to be tested are as the below mentioned :  Al, Fe & Cu Metal Content Color (ASTM) Kinematic Viscosity at 40 Deg. C. Total Acid Number Water Content (Karl Fischer)     Kindly confirm receipt of our enquiry. This is for your kind information and necessary action. For any further clarifications, feel free to contact me.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].