• Home
  • Archive by category "Lube Oil Analysis"

Engine Oil Condition Analysis in Safat, Kuwait

Enquiry:

I am writing to seek your services in assisting us to do an engine oil condition analysis for our fleets based on below;

Please provide us with your office location and contact numbers in Kuwait for further discussion on the same.

  1. 12,000 km   – 3 samples
  2. 15,000 km   – 3 samples
  3. 18,000 km   – 3 samples

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Engine Oil testing (Gas genset) in Oman

Enquiry:

We need to do engine oil testing. Pl find attached oil test method.

Viscosity at 100 °c (mm2/s) Total base number TBN (mgKOH/g) Total acid number, TAN (mgKOH/g) iph value Water (% by vol.) Glycol (mg/kg) Oxidation (A/cm) Nitration (A/cm) Wear elements (mg/kg): Iron (Fe) Lead (Pb) Aluminum (Al) Copper (Cu) Tin (Sn) Silicon (Si) Test method ASTM 0445 DIN 51562 ASTM 02896 ISO 3771 ASTM 0664 ASTM 07946 ASTM 06304 EN 12937 ISO 6296 ASTM 02982 DIN 51453 DIN 51453 DIN 51399-1/-2 Llmit values for Series 4000 Max. 17.5 Min. 11.5 Min. 2.5 and TBN > TAN max. new oil value +2.5 Min. 4 Max. 0.2 Max. 100 Max. 20 Max. 20 Max. 30 Max. 20 Max. 10 Max. 20 *** Max. 5 Max. 15* Llmit values for Series 400 New oil value +30 % ** New oil value -60 % ** On request from factory Min. 4 Max. 0.2 On request from factory Max. 30 Max.30 Max.50 Max. 30 Max. 20 Max.50 Max. 15 Max. 10 *

  • The limit value for the wear element Si only refers to natural gas operation.
  • * New oil value can be requested from the factory
  • * * During the 1st oil change (max. 3000 op. hrs.), the limit value is 50 ppm.
    Table 2: Limit values for used gas engine oils SAE 40
    Used-oil analysis
    The results of the oil analyses must be archived.

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Used Thermic Fluid Testing in India

Enquiry:

We have requirement of USED THERMIC FLUID OIL Testing Charges .Below parameters need to test . Kindly share your best quotation to proceed further.

NO OF SAMPLES : 2 EA

1.viscosity @100 F

2.Acid Number

3.Moisture

4.Low boilers

5.High Boilers

6.Flash point

7.insoluble solids


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube, Grease, Transformer oil Analysis in Jeddah, KSA

Enquiry:

Please send us your competitive oil analysis offer for the attached files for the purpose of an annual contract.

Transformer Oil:

Sr. No.Test ParametersTest MethodUnit Price (SAR)
1ColorASTM D1500 
2AppearanceASTM D1524 
3Acidity (Neutralization  Number)ASTM D974 
4Interfacial TensionASTM D971 
5Water ContentASTM D1533 
6Dielectric break down Voltage 2.5mm gapASTM D877 
7Dielectric break down Voltage 1 mm gapASTM D1816 
8Dielectric break down Voltage 2.5 mm gapIEC 60156 
9Dielectric Dissipation Factor @90°IEC 60247 
10Oxidization Stability 72 Hours @110°IEC 61125C 
11Oxidization Stability 164 Hours @110°IEC 61125C 
12Power Factor at 25°ASTM D924 
13Power Factor at 100°ASTM D924 
14Copper Corrosion @150 ° for 48 HoursASTM D1275 B 
15Specific Gravity at 60/60°ASTM D1298 
16Flash Point COC °ASTM D92 
17Dissolved Gas by GC (IEEE Std)ASTM D3612 
18Viscosity @40°ASTM D445* 
19Polychlorinated Biphenyls (PCB’s) by GCASTM D4059 
20Pour PointASTM D79 
21DBDSIEC 62697 
22CCDIEC 62535 
23PassivatorIEC 60666 
24Particle countASTM D6786** 
25Trace Metals (Cu, Fe, Al, Ni, Zn, Si, Na, Ca, Mg)ASTM D7151 
26FURAN Compound (5 compounds)ASTM D5837 
 
27Oxidation inhibitor by GCASTM D4768 
28Oxidation Stability by RBOTASTM D2112 
29Sediment and Soluble SludgeASTM D1698 
30Specific Resistance @25 Deg CASTM D1169 
31Specific Resistance @90 Deg CASTM D1169 
32Degree of PolymerizationASTM D4243 
33Degree of Polymerization (Calculation)***Calculation 
34Refractive IndexASTM D1218 
35Total SulfurASTM D4294 
36Oil Profile TestASTM D2140 

Grease Testing:

Lube Oil Testing:


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Turbine Lubricant Oil Testing in Fujairah, UAE

Enquiry:

With regard to mention subject, Kindly let us know your proposal  for collecting from 6 to 8 sample for testing turbine oil,

Its already  barrel stored  and we need to check its validity

Your quick response is highly appreciated.

SCOPE OF WORKLubricant Turbine Oil (T32) Testing
LOCATIONFujairah UAE.

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lubricant Oil Testing in Jubail, KSA

Enquiry:

We have a requirement for Oil test analysis for lube oil. Let me have your contact details to send the sample oil for testing.

Oil is available at site (Jubail)

If you require any further information, feel free to contact me.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].