• Home
  • Archive by category "Enquiries"

Oil Contaminated Water Testing, Qatar

Enquiry:

Kindly furnish your Technical and Commercial proposal along with Service Duration for the subject job scope.

Scope:

Required parts / Service to rectify the defects (Material Description)QuantityUOM
contaminated oily water  laboratory Analysis 1. pH 2. COD 3. TSS 4. OIL And GREASE 5. SULFIDE 6. PHENOLS5pcs

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Vessel Fresh Water Testing, Fujairah

Enquiry:

Pls kindly advise the cost, duration and availability of Fresh water test @Fujairah. ETA 23rd Mar.
We hope to receive your quotation ASAP. If you need any other information,  feel free to let us know.
Our company is a worldwide service agent in Shanghai China. Your prompt reply will be highly appreciated.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].

Diesel Testing Periodic Contract, Abu Dhabi

Enquiry:

Please quote your best offer and lead time for the Diesel Fuel Testing,

  1. Diesel Quality Testing (for Project) – Twice a week
  2. CHARGES ONLY FOR THE SULFUR CONTENT TESTING IN DIESEL FUEL
  3. CHARGES FOR THE DETAILED QUALITY TESTING [CHEMICAL COMPOSITION TESTS] IN DIESEL FUEL

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing Contract, Kuwait

Enquiry:

Please provide your best offer prices for the attached request for the Transformer Oil Analysis,

Please consider the number of samples approximate 20,000 -/ to provide your best price offer.

Tests (For Transformer Oil Analysis)Test Method
AppearanceExamined Visually At Ambient Temperature
Visoos ty Ai 40 °cIS03 104 Or ASTM D445
Visoos ty At —30 °cIS03104 Or ASTM D445
Pour Point 0cIS03016 Or ASTM D97
Demity At 20 °cIS03675 Or ISO12185
Water ContentIEC.60814 Or ASTM D1533
Dielectric Strength (Breakdown Voltage)IEC.60156 Or ASTM D1298
Dielectric Dissipation Factm (DDF) At 90 °cIEC.6024
AcidityIEC.6202 1— l   Or ASTM D974
Aniline Point 0cASTM D66l
Interfacial Tension at 20°cISO,   6295 Or ASTM D971
Total Sulphur ContentBS 2000 Part 373 Or ISO 14596
Corrosive SulpherIEC.62534 And ASTM D I275 B
Inhibitor ContentIEC.60666
Fmrfural ContentIEC61 198
Oxidation StabilityIEC61125C, Telst Duration 164 Hour , If Inhibitor Content Is <0.01% (Note 1) IEC60247
Total Acidity
Sludge
-Dielectric Dissipation. Factm At 90°c
Flash PointISO2719
Polycyclo Aromatic Content (PCA)BS2000 Part 346
PCB ContentIEC61619

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Truck Mounted Analyzers Calibration, Saudi Arabia

Enquiry:

We are Trading co in Gulf, based in Jubail, specialized in field of Environmental & pollution control services to SABIC / ARAMCO. Therefore, seeking for certified 17025 and authorized calibration services shall be approved in Royal commission as well. We owned following Analyzers racks on truck mounted with quantity 07/station.

Could you please advise further your other technical expertise and I expect your earlier response and willing to be having best business relation soon with you.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].

Water Quality Testing Contract, Sharjah

Enquiry:

We are seeking from professional companies to submit their Priced quotation for water quality testing at Sharjah.

Description of the work:

  • Tests to be done – Chemical Test, Legionella Test, & Microbiological test
  • Sample Should be collected from the site
  • Frequency of service as follows,
  1. Water Tanks – 14 No’s – Quarterly
  • Water Feature – 1 No. – Quarterly
  • Swimming Pool – 1 No. – Monthly

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].

Crude Assay Test for Export Crude Sample, UAE

Enquiry:

Would you please quote for below requirement?

NODescriptionUOMQTY
1Assay of export crude oil sample as per requirements detailed in SOWEA2

Crude Test Parameters:
• Density @20oC ASTM D1298 or D5002
• API @60oF ASTM D1298 or D5002
• Composition by GC (to C10 or similar) ASTM D2427
• Kinematic Viscosity @ 40oC and 60oC ASTM D0445
• H2S UOP163
• Mercaptan Sulfur UOP163
• Sulphur ASTMD2622 or similar
• Total Nitrogen ASTM D5762
• Acid Value ASTM D664
• Flash Point ASTM D93
• Pour Point ASTM D5853
• Wax Content UOP46
• Atmospheric Distillation ASTM D86 or D1160
• Water Content ASTM4007
• Salt Content ASTM D3230
• Sediment by Extraction ASTM D473
• Vapour pressure/RVP ASTM D5191/6377
• Yield on Crude ASTM D2892 or D5236
• Aromatics (FIA) ASTM D1319
• Naphthanate Content


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].