• Home
  • Archive by category "Pakistan"

Lube Oil Testing in Baluchistan, Pakistan

Enquiry:

We require lab analysis of lubrication oil sample. Oil Type: SAE-30

You are requested to provide your quotation for the following test:

1. Physical Characteristics

  • Viscosity at 100°C (cSt)
  • Viscosity Index
  • Flash Point (Pass/Fail), °C
  • TBN (ASTM D2896), mg KOH/g

2. Wear Metals

  • Iron (Fe), ppm
  • Chromium (Cr), ppm
  • Tin (Sn), ppm
  • Lead (Pb), ppm
  • Copper (Cu), ppm
  • Nickel (Ni), ppm
  • Aluminium (Al), ppm

3. Contamination

  • Water Content (AquaTest), %
  • Sodium (Na), ppm
  • Silicon (Si), ppm

4. Oil Condition

Overall oil condition assessment.

Kindly provide your best quotation along with applicable testing Santander/methods and expected turnaround time for lab analysis report.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Environmental, Asbestos Testing in Peshawar, Pakistan

Enquiry:

We are Environment and Education Services, a consultancy firm based in Peshawar, providing environmental consulting and social services for projects in Khyber Pakhtunkhwa under the supervision/compliance requirements of the World Bank and Asian Development Bank (ADB). Currently, we are expected to be involved in the rehabilitation of an existing government building for environmental and asbestos testing. As part of the rehabilitation work, some demolition activities will also be carried out. The donor has advised that a short Environmental and Occupational Health & Safety (OHS) assessment be conducted, along with a mitigation plan. As an initial step, we need to determine whether any asbestos-containing materials (ACMs) are present within the building or its components. Based on the laboratory findings, a detailed mitigation plan will subsequently be prepared to ensure the protection of workers and the environment from potential asbestos-related hazards. For this purpose, we will collect samples in accordance with approved SOPs, properly seal and label them, and deliver them to your site office in Peshawar for laboratory analysis.

We kindly request you to provide your quotation for the following:

1.      Laboratory testing/analysis per sample using Polarized Light Microscopy (PLM) or any other appropriate/approved analytical method.

2.      Cost per sample, including sampling and laboratory analysis.

3.      Cost per sample excluding sampling.

Please also mention the applicable turnaround time for the analysis and any other relevant requirements for sample submission. 


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Vegetable Acid Oil Testing in Karachi, Pakistan

Enquiry:
We require below test in sample ofvegetable acid oil.

The analysis should be based on testing for the following:

NoTest
1Moisture & Volatile matter
2Insoluble impurities
3Unsaponifiable Matter
4Polyethylene
5Free Fatty Acid as Oleic Acid
6Sulfur content
7Inorganic Chlorides
8Organic Chlorides
9Total Nitrogen
10Phosphorus (P)
11Iron (Fe)
  12Total Metals (Ag, Al, B, Ba, Cd, Ca, Cu, Cr, Fe, Mg, Mn, Na, Ni, K, Mo, Pb, Si, Ti, Sn, Zn, Li, Sb)

 Kindly inform us if the above tests are possible and what will be the sample quantity cost ( advise separate test charges ) and time required for providing results of the tests

Your urgent attention will be highly appreciated. 


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

TBC and Legionella Testing Certified Labs

TBC (Total Bacterial Count) and Legionella testing are two different types of microbiological water tests, each serving a different purpose.

1. TBC (Total Bacterial Count)

Also called:

  • Total Viable Count (TVC)
  • Heterotrophic Plate Count (HPC)

Purpose:
Measures the total number of viable bacteria present in a water sample. It does not identify specific bacteria or indicate whether they are harmful.

Common uses:

  • Drinking water quality monitoring
  • Process water testing
  • Cooling towers
  • Hospital water systems
  • Food and beverage industries

Typical method:

  • Plate Count Agar (PCA) or similar media
  • Incubation at specified temperatures (commonly 22°C and/or 36–37°C) for defined periods
  • Results reported as CFU/mL (Colony Forming Units per milliliter)

Interpretation:

  • Low counts generally indicate good microbiological quality.
  • High counts may suggest poor sanitation, biofilm formation, or stagnation, but they do not necessarily indicate the presence of pathogens.

2. Legionella Testing

Purpose:
Detects and quantifies bacteria of the genus Legionella, particularly Legionella pneumophila, which can cause Legionnaires’ disease.

Common sources tested:

  • Cooling towers
  • Hot and cold water systems
  • Hospitals
  • Hotels
  • Spa pools
  • Decorative fountains

Testing methods:

MethodDetectsTime to Result
Culture (ISO 11731)Live Legionella7–10 days
qPCRLegionella DNAFew hours to 1 day
Rapid antigen testsSpecific targetsMinutes to hours (limited use)

Results:

  • Reported as CFU/L for culture methods.
  • qPCR results are typically reported as genome copies per liter or similar molecular units, depending on the laboratory.

Comparison

FeatureTBCLegionella
MeasuresTotal viable bacteriaSpecific Legionella bacteria
SpecificityNon-specificHighly specific
Indicates pathogens?NoYes
Typical unitCFU/mLCFU/L
Main purposeGeneral water hygienePublic health risk assessment

Why both tests are often performed

A water system can have:

  • Low TBC but detectable Legionella, or
  • High TBC but no Legionella.

Because of this, TBC cannot be used to confirm or rule out the presence of Legionella. For systems with a risk of aerosol generation (such as cooling towers, healthcare facilities, hotels, and large building water systems), Legionella testing should be performed separately as part of a water safety management program.

If you’re working with a particular standard (such as ISO, WHO guidance, ASHRAE, or local regulations), the testing frequency and action limits may differ. I can also explain the relevant requirements for those standards.

Interested in Learning more about water testing, Visit our dedicated water testing services page: WATER TESTING

TBC and Legionella Testing Labs

Transformer Oil DGA, Ageing, Furans Testing in Lahore, Pakistan

Enquiry:

We are currently preparing a commercial offer for our client, covering a 2-year transformer oil analysis contract by a foreign laboratory, we’d like to request a quotation directly from your team.

Scope of testing required:

1. Transformer Oil DGA Analysis (as per IEC 60567/60599) – 20 samples

2. Transformer Oil Ageing – Acidity, BDV, DDF (as per IEC standard) – 20 samples

3. Transformer Oil Paper Ageing – Furans & Methanol (as per IEC standard) – 14 samples

Additional scope requirements:

– 50% of samples tested in Year 1, remaining 50% in Year 2

– Supplier to provide sampling kits to our site team

– Supplier to arrange/advise on dispatch logistics of oil samples from Pakistan site to your nearest UAE facility

– A comprehensive technical report per batch, including interpretation of results, condition assessment, comparison against historical/online DGA data, and clear recommendations for corrective/preventive action

The 10 transformers involved are ___ and unit auxiliary transformers (220kV/22kV and 220kV/18.5kV/11kV class); full equipment list available on request.

Could you please share, or point us to the right regional contact for:

– Per-sample pricing for each test category

– Sampling kit cost (if chargeable)

– Estimated freight/logistics cost and lead time from Pakistan to your UAE facility

– Typical turnaround time per batch

– ISO/IEC 17025 accreditation scope covering these tests

Our submission deadline is 27 July 2026, so we would greatly appreciate a prompt response, ideally within 3-4 working days.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Industrial Environmental Testing in Karachi, Pakistan

Enquiry:

Kindly let us have quotation for environmental testing service for our company. We are in inks production business a joint venture of Printing corporation.

The required tests details are attached.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

TCLP Test for Beads Waste Disposal, Lahore, Pakistan

Enquiry:

We want to perform the TCLP test for the wastage of used aluminum oxide beads.

These beads are utilized for cleaning of metallic parts of turbocharger at beads blasting machine, pls check & share your quotation for this test.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Coolant Sample Testing in Islamabad, Pakistan

Enquiry:
We are looking for a laboratory to perform testing and analysis of a coolant sample. Kindly provide us with your quotation for testing the following parameters:

  1. Boiling Point
  2. Freezing Point
  3. Mono Ethylene Glycol (MEG) Ratio / Concentration
  4. Anti-Rust Agent
  5. Anti-Scaling Agent

Please also include the following information in your quotation:

  • Test methods/standards used
  • Sample quantity required
  • Turnaround time for the test results
  • Cost breakdown (if applicable)
  • Any other requirements for sample submission

We would appreciate receiving your quotation at your earliest convenience.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].