• Home
  • Archive by category "Saudi Arabia"

Weighing Scales Calibration in Jeddah, KSA

Enquiry:

We are a small factory for ice cream cone & biscuit in Jeddah, Saudi Arabia.

We would like to have your service of weighing scales calibration for the following scales:

  1. 15 kg

range is 40 g – 15 kg

division 2 g

  1. 150 kg

range is 200 g – 150 kg

division 10 g

We would like to discuss the details of the service and quotation with your sales representative.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

PMB Binders Sample Testing as per AASHTO M 332, KSA

Enquiry:

Regarding the PMB binder samples the required testing is as following:

  1. The PMB PG 70 – 10 with 3.5% SBS, we need the PAV (Presser Aging Vessel) following testing:
    DSR G*x sin δ (dynamic sheer rheometer) @ 34 C°.
    BBR S (creep stiffness) & m-value (bending beam rheometer) @ 0 C° actual testing temperature.  
  2. The PMB PG 76 – 10 with 5.5% SBS, we need the PAV (Presser Aging Vessel) following testing:
    DSR G*x sin δ (dynamic sheer rheometer) @ 37 C°.
    BBR S (creep stiffness) & m-value (bending beam rheometer) @ 0 C° actual testing temperature.

Acceptance criteria according to AASHTO M 332 and attached picture.   


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Borewell Water Testing Contract in Riyadh, KSA

Enquiry:

We need to have water analysis in Saudi at below location:
We need full/ complete water analysis including radioactive substance analysis etc.
Please share your quote for water analysis service for multiple locations across Riyadh city, Saudi Arabia.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Sewage Water Testing in Al Khobar, KSA

Enquiry:

Please provide us your best quote for below Sewage sample analysis.  

The following Parameter to be analyzed of Sewage Sample.

Physical Parameters

pH : 6.5 – 9.0
Turbidity : 2 N.T.U.
Total Dissolved Solids : 3500 mg/l
Total Suspended Solids : 10 mg/1
temperature : DT +/-3
Floating Particles : Nil

Chemical, Organic & Inorganic

B.O.D. : 10 mg/1
Ch. Oxygen Demand : 40 mg/1
Dissolved Oxygen : MINIMUM 5 mg/1
Fat, Oil and Grease (Emulsified) : 5 mg/1
Ammonia(As Nitrogen) : 1 mg/1
Nitrate (NO3) as N : 5 mg/1
Nitrite (NO2) as N : 0.5 mg/1
Total Kjeldahl Nitrogen : 5 mg/1
Total Nitrogen : 10 mg/1
Total Organic Carbon (TOC) : 10 mg/1
Sulphate : 300 mg/1
Sulphide : 0.05 mg/1
Residual Chlorine : 0.5 mg/1
Total Phosphate (P) : 1 mg/1

Microbiological

Total Coliforms : <2.2 colonies/100 ml l
Helminth eggs : <0.1/1000ml egg/l
Parasitic Helminth Worms : Absent worm.L

Inorganic Compounds and heavy metal

Fluorescent Petroleum Materials : 0.1 mg/l
Hydrocarbons : 5 mg/l
Phenols : 0.002 mg/l
Chlorides : 1500 mg/l
M.B.A.S : <5 mg/l
Aluminium : 1 mg/l
Copper : 0.2 mg/l
Iron : 1 mg/l
Nickel : 0.1 mg/l
Lead : 0.1 mg/l
Cadmium : 0.01 mg/l
Total Cyanide : 0.05 mg/l
Zinc : 0.5 mg/l
Total Chromium : 0.02 mg/l
Cobalt : 0.05 mg/l
Manganese : 0.2 mg/l
Bicarbonate : 400 mg/l
Sodium : 200 mg/l
Magnesium : 60 mg/l
Calcium : 200 mg/l
Sodium Absorption Ratio : 6 mg/l
Beryllium : 0.1 mg/l
Fluorides : 1.5 mg/l
Lithium : 2.5 mg/l
Selenium : 0.05 mg/l
Vanadium : 0.1 mg/l
Barium : 2 mg/l
Mercury : 0.001 mg/l
Molybdenum : 0.01 mg/l
Boron : 1 mg/l
Arsenic : 0.05 mg/l


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Filtering, Vacuuming, BDV Test in Jeddah, KSA

Enquiry:

We have an ongoing project at Shuaibah Jeddah region and are looking for the service for below.

Also along with this email I have attached the Scope of Work details, could you please look into the requirement and revert back to the email along with the quote.

Sr. No.MaterialItem DescriptionUOMQty 
13rd Party Service for Transformer Oil filtration works including Filtering, Vacuuming,  Oil Break Down Voltage test and Oil analysis test.                                                                                       Oil Capacity – 58000LtrTransformerno’s2 

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil and Water Test in Jeddah, KSA

Enquiry:

We are working for one of our clients who needs the testing of Transformer Oil and Water testing on a periodic basis. 

Appreciate if you can share with us your quotation for the above requirement. The site is located within 100-150km around Jeddah. 


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Raw Water Analysis in Madinah, KSA

Enquiry:

We have been awarded a project at Taiba which is located approximately 105 km to the south east of Madina in the Kingdom Saudi Arabia.

With regards to above please note that we have a requirement of conducting raw water analysis at the project site as per attached specification.

As a major Laboratory for conduction such kind of analysis we invite your services for the subject requirement.   

Please submit your best offer with a detailed company profile, reference lists etc.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Testing in Madinah and Qassim, KSA

Enquiry:

We have signed 2 power plant projects in Medina and Qassim, and have a need of subcontracting of raw water sampling and testing.

The raw water is from local sewege treatment plant, which requires your lab is capable of sampling under your relationship with the plant or approval from relevant authorities. 

Let me know If your lab has an interest on our projects, and I will share the specification requirement for you to know more about our need.

Also I am in Saudi these days, and maybe we can meet face to face.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Jet Engine Oil and Hydraulic Testing in Riyadh, KSA

Enquiry:

I need your support in laboratory test, to define the water content in oil sample by using (KF) Karl Fischer with the Aquatest 2010. 

The required unit is (PPM) Part Per Million.

The oil samples are:

1. Hydraulic oil.

2. Jet engine oil.

Can you please provide me with a quotation for the test per sample?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].