• Home
  • Archive by category "Water Analysis"

Seawater Testing in Riyadh, KSA

Enquiry:

 Kindly send offer for the Test for particle size analysis of solids in seawater.

Testing shall include:

Particle Size Distribution

Measured by Laser Diffraction in accordance with ISO 13320.

Results shall report:

  • D10, D50, D90 (µm)
  • Full PSD curve
  • Percentage by volume in ranges:
    • <1 µm
    • 1–5 µm
    • 5–20 µm
    • > 20 µm

Particle Count

Measured by ISO 21501 or equivalent:

  • 2 µm
  • 5 µm
  • 10 µm
  • 25 µm

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Emission, Water, Environmental Testing in Pakistan

Enquiry:

Kindly quote your best rates for the following test at Gulshan-e-Iqbal, Karachi on Urgent basis.

1. Gaseous Emission Tesing of Hovel Boiler1 Particulate Matter (By using 0.45 u filter paper)2 Sulphur Dioxide (SOz)3 Oxides of Nitrogen (NOx)Carbon Monoxide (CO)
2. Gaseous Emission Test (Chiller)Particulate Matter (By using 0.45 u filter paper)Sulphur Dioxide (SOz)Oxides of Nitrogen (NOx)Carbon Monoxide (CO)  
3. Noise Level Testing of Blow Molding MachinesNoise Level Testing per point
4. Waste Water TestingEffluent FlowTemperature Free of Cost pHBiochemical Oxygen Demand (BODs) 2,500Chemical Oxygen Demand (COD) 2,5O0Total Suspended Solids (TSS) 700Total Dissolved Solids (TDS) 700Grease & Oil 800Chloride (Cl) 700Phenolic Compound
5. Vehicle Emission Testing (Diesel Fork Lifters)Carbon Monoxide (CO)Smoke PointNoise
6. Vehicle Emission Testing (Toyota Hilux)Carbon Monoxide (CO)Smoke PointNoise
7. Vehicle Emission Testing (Toyota Vigo)Carbon Monoxide (CO)Smoke PointNoise
8. Granulator Room Noise TestNoise Level per point
9. Drinking Water Test.Bacteriological Analysis1 Total Coliform, Fecal Coliform, Escherichia Coli (E-Coli)2 Physical(i) Color(ii) Taste(iii) Adour(iv) Turbidity, NTU(v) Total Hardness as CaCO 3(vi) Total Dissolved Solids (TDS)(vii) pH3 Chemical
10. Soil Sample Testing1. pH Value L,70A2. Grease & Oil 2,5003. Arsenic (As) 6,6004. Barium (Ba) 4,8005. Cadmium (Cd) 4,8006. Chromium (Cr) 4,8007. Lead (Pb) 4,8008. Zinc (Zn) 4,8009. Silver (Ag) 4,80010.Selenium (Se) 4,80011. Mercury (Hg) 6,50012
11. Noise Testing of Diesel Fire Engine
12. Noise Testing of Boiler Room
13. Gaseous Emission of Diesel Fire Engine


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Drinking Water Quality Testing in Riyadh, KSA

Enquiry:

We would like to conduct a drinking water quality test for our office. Kindly provide your quotation for the water quality analysis covering the parameters listed below:

  1. pH
  2. Total Dissolved Solids (TDS)
  3. Alkalinity
  4. Color
  5. Oduor
  6. Turbidity
  7. Hardness
  8. Chloride
  9. Fluoride
  10. Nitrate
  11. bromate
  12. Lead
  13. Arsenic
  14. Cadmium
  15. Mercury
  16. Iron
  17. Coliform
  18. E. coli
  19. Total Bacteria Count
  20. Trihalomethane

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Testing in Rotterdam, Europe

Enquiry:
We would like to request your support for testing a water sample intended for use in mixing refractory castable material for our Project, at Botlek, theemsweg Rotterdam.

The following tests are required for the water sample as per API 936 requirement.

  1. Chloride Content
  2. pH Value

Kindly confirm:

  • Applicable testing standards
  • Sample quantity required
  • Turnaround time for test results
  • Cost and any additional requirements

Once confirmed, we will arrange for submission of the water sample at the earliest.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Air Quality, Noise, Water Testing in Sharjah, UAE

Enquiry:

Could you please let me know the process and testing cost for minimum the following items to make sure those are in compliance with environmental regulations and safety standards settled by Sharjah Municipality. Consider top priority and contact the undersigned for any further queries / site visit.   

  • Air Quality at our factory premises (may be in and out) 
  • Water Quality (Line Water & Drinking Water) 
  • Noice Level  (In reference to industrial area standard decibel)

The purpose of the testing is to renew the company license & apply ISO. 


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Ballast Water Sampling and Testing in Port Said, Egypt

Enquiry:

We work with Korea’s shipowner regarding BWTS VGP SAMPLING.

Could you give us a quotation for VGP Sampling(on board testing and Laboratory Analysis) as below conditions? (Incl. travel expenses);
1. Vessel name: ____________
2. Port of collection / Date: Port Said, Egypt / ETA 11-May-2026(LT)
3. BWMS Model / Type: GloEn-Patrol (Maker: PANASIA CO., LTD.) / Filter+UV
4. BWMS Q’ty / Sampling point: One system / one sampling point
5. REMARK: BIOLOGICAL


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Waste Water Testing in Al Malaz Riyadh, KSA

Enquiry:

We are currently looking for a company that can provide wastewater test analysis services. Kindly share your contact details, including your name, email address, and other relevant information, so we can send our official communication.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Microbiological Testing Annual Contract in Riyadh, KSA

Enquiry:

Kindly provide your best offer for Annual Microbiological Analysis Test, please take a note that:

  • Certification body must be accredited.

Please find the below table only for 20 tests/samples

GroupTest NameNo. of Test/ Sample
Surface Swab TestTPC2
M & Y2
Col.2
Hand Swab TestSalmonnella1
E.Coli Sp.1
Air TestTPC1
M & Y1
Water Micro TestE.Coli2
Total Coliforms2
Pseudomonas Aeruginosa2
Faecal Streptococci2
Suphic-Reducing Clostridia2
AreasMicrobilogical TestsSurface Swab TestHand Swab TestAir TestWater Micro TestTotal Tests (per year)
TPCM & YCol.SalmonnellaE.Coli Sp.TPCM & YE.ColiTotal ColiformsPseudomonas AeruginosaFaecal StreptococciSuphic-Reducing Clostridia
Test Technique / Method ReferenceAOAC990.12ISO21527-1AOAC991.14ISO6579-1 APHA-Compendium Chapter3APHA-Compendium Chapter3ISO7899AS 4276.5AS4276.13 ISO15213
Printing & Sheeting             
WIP Material (after printing /sheeting)            0
Part of the Machine touching the material            0
Operator / Line Crew / QC Technician            0
Near the machine       xxxxX5
Die Cutting & Lamination             
WIP Material (after die cutting & lamination)     XX     2
Part of the Machine touching the product            0
Operator / Line Crew / QC Technician            0
Near the machine       xxxxX5
Finishing & Molding             
Final Product (from the box/conveyor)XXX         3
Part of the Machine touching the productXXX         3
Operator / Line Crew   XX       2
Operator / Line Crew / QC Technician            0
Near the machine            0
Total Tests20

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

BWMS Plants Calibration, Water Testing of Vessels

Enquiry:

PLEASE OFFER FOR VARIOUS CALIBRATIONS AND D2 WATER TESTING FOR OUR BWMS PLANTS INSTALLED ONBOARD.

NUMBER OF VESSEL – 11

TYPE – BULK CARRIER

MAKER – ——— China (10 VESSEL)

             – JAPAN (01 VESSEL)

LOCATION – SINGAPORE, CHINA, BANGLADESH, INDIA


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].