Ready to Use Liquid Disinfection Cleaner Testing in Qatar

Enquiry:
I am reaching out to inquire about your testing and certification capabilities for our product line, specifically a Ready-to-Use Liquid Disinfectant Cleaner for Airline . We are seeking an accredited laboratory to conduct testing and issue compliance certificates/declarations for the following:

Microbiological & Efficacy Testing Standards (or Equivalent)

  • EN 1276: Suspension test for establishing whether a chemical disinfectant or antiseptic has bactericidal activity.
  • EN 13727: Suspension test designed to measure bactericidal activity of chemical disinfectants and/or antiseptics.
  • EN 13697: Quantitative non-porous surface test for the evaluation of bactericidal and/or fungicidal activity of disinfectants used in food, industrial, domestic and institutional areas.
  • EN 1650: Quantitative suspension test for the evaluation of fungicidal or yeasticidal activity of chemical disinfectants and antiseptics used in food, industrial, domestic and institutional areas.
  • EN 14476: Quantitative suspension test for the evaluation of virucidal activity of disinfectants intended for use in the medical area.
  • EN 16777: Quantitative Non-porous Surface test without Mechanical action for the Evaluation of Virucidal activity of Chemical Disinfectants used in Medical Area (10 min).

Aviation & Aerospace Material Compatibility Certifications

  • Boeing D6-7127 Rev. P: Boeing D6-7127 Rev. P Certificate.
  • AMS 1550B: AMS 1550B Certificate.
  • AMS 1453-BSS7434: AMS 1453-BSS7434 Certificate.
  • Airbus CML 14-012: Airbus CML 14-012 Certificate.

Safety, Transport & Regulatory Declarations/Testing

  • Regulation EC no. 1907/2006 REACH: Declaration of compliance confirming product(s) meet the requirements laid in Regulation EC no. 1907/2006 REACH.
  • General Product Safety Directive EC/2001/95: Declaration of compliance confirming product(s) meets the requirements laid in the General product safety directive EC/2001/95.
  • Flammability Test: Flammability test (flash point) in compliance with FAA/IATA requirements.
  • IATA Non-Restricted Item Declaration: Declaration of compliance with International Air Transport Association (IATA) as a non-restricted item.

Please let us know:

  1. Which of the above tests and certifications your facility can perform directly (or facilitate through your accredited global network).
  1. Required sample quantities and lead times for testing.
  1. The quotation or pricing structure for these services.

If required, we are happy to arrange a brief call for further review.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Design Validation Testing of Valves in Oman

Enquiry:

we are a Valve manufacturing facility in Oman and are looking for vendors who can conduct Design Validation Testing of Valves as MESC 77/300.

We have a requirement of testing for 2 valves. (valves will be free issued to FITECH).

  1. 8” x 2500# Trunnion Mounted Ball Valve, RB, Soft Seated, gear operated, Raised Face – 01 Valve
  2. 1 ½” x 2500# Floating Ball, Soft Seated – 01 Valve

The sequence as per MESC 77/300 will be 8. Bi-dir.≥-29°C<0°C>80°C≤200°C

Design Temperature of both valves are:  Minimum: -29 Deg C and Maximum: + 120 Deg C.

Do you have testing tool for torque measurement at various stages which is part of DVT.

Do you have Mechanical Cycling fixture/set up which is also part of DVT at various stages.

Requesting you for your best offer and the timeline required to successfully complete the DVT. Also please share the PTR for any previous jobs executed wherein TAT was performed at your facility.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Class 1 Medical Devices Testing, Certification in Riyadh, KSA

Enquiry:

We are currently seeking qualified laboratory service providers to conduct testing for Class I medical devices, including single-use cusco speculums and speculum kits.

The test reports will be used as part of our product initial registration and certification submissions to the Saudi Food and Drug Authority (SFDA).

We kindly request your laboratory to confirm whether it can perform some or all of the following tests at your facility or accreditated subcontractors:

  1. Accelerated Aging Test
  2. Bioburden Test
  3. Seal Strength Test
  4. Seal Integrity / Leak Test
  5. Biocompatibility Testing – Biological Evaluation
  6. Transport Validation Test
  7. Sterility Test
  8. Bacterial Endotoxins Test – LAL Test

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chemical Compatibility Testing Demulsifier Inhibitors Khafji, KSA

Enquiry:

We are requesting technical and commercial proposals from qualified laboratories to conduct Chemical Compatibility Testing between production Demulsifiers and Corrosion Inhibitors. Our demulsifiers and inhibitors are the following:

  • Corrosion Inhibitors
  1. CRW22051
  2. CRW22529
  • Demulsifiers
  1. DMO22758
  2. PHASETREAT 19745
  3. MC MX 1-6000
  4. Duradem 3901

The objective of this study is to evaluate potential incompatible interactions between these surface-active chemicals to prevent emulsion stabilization, foaming, or degradation of corrosion mitigation efficiency within production facilities.

1. Scope of Work

The selected laboratory will be required to perform the following evaluations using representative fluid samples provided by –:

  1. Physical Compatibility / Blend Testing: Visual assessment of neat chemical blends at varying ratios to check for precipitation, turbidity, or phase separation.
  2. Emulsion Bottle Testing: Bench-scale evaluation at simulated field temperatures to measure water drop rate, interface clarity, and residual BS&W across various chemical dosage matrices.
  3. Corrosion Efficiency Testing: Linear Polarization Resistance (LPR) or Electrochemical Impedance Spectroscopy (EIS) to confirm that the demulsifier does not degrade the protective film efficiency of the corrosion inhibitor.

2. Technical Data & Field Conditions (Approximate)

  1. Fluid Matrix: Crude Oil (~27–28° API), High-Salinity Produced Water
  2. Average Water Cut: 28% to 32%
  3. Operating Temperature: 38°C to 64°C
  4. Chemical Types: MSDS attached.
  • Submission Requirements

Please include the following details in your formal proposal:

  1. Technical Proposal: Detailed testing methodology, equipment specifications, applicable ASTM/NACE standards, and standard fluid volume requirements.
  2. Commercial Proposal: Itemized cost breakdown per test/matrix run and total project cost.
  3. Timeline: Estimated turnaround time from sample receipt to final report delivery.
  4. Qualifications: Key laboratory accreditations (such as ISO 17025) and relevant experience with GCC fluid systems.

We look forward to receiving your proposal.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

HVAC Performance and Safety Testing in Doha, Qatar

Enquiry:

Aerodynamic and acoustic performance testing on our new plastic under-seat displacement ventilation diffusers

We are seeking an accredited third-party laboratory to perform aerodynamic and acoustic performance testing on our new plastic under-seat displacement ventilation diffusers. These components will be deployed in a major open-air stadium project.

We require certification in strict accordance with ANSI/ASHRAE Standard 70 (or BS EN 12238 / BS EN 12239 equivalent metrics).

 Required Testing Scope

The laboratory testing must evaluate and chart the following specific schedule parameters:

  1. Design Air Flow Rate: Performance mapping across a range of volumes measured in Liters per Second (L/S).
  2. Nozzle Discharge Velocity: Centerline velocity measurements measured in Meters per Second (M/S).
  3. Acoustic Performance: Noise Criteria (NC) Level rating derived from octaval sound power testing in a reverberation room.
  4. Maximum Pressure Drop: Resistance measurements across the assembly measured in Pascals (Pa).

Product Spec Summary

  • Component Type: Floor / Riser Mounted Under-Seat Displacement Diffuser
  • Material Composition: Injection-molded plastic polymer (UV stabilized)
  • Sample Units Available: [Insert number, e.g., 3] production-ready samples can be shipped immediately.

Request for Quotation (RFQ) Requirements

Please reply with your introductory proposal including:

  • Cost estimate for the full performance test and final stamped report generation.
  • Standard lead time from sample receipt to official data delivery.
  • Accreditations held by your facility (e.g., ISO 17025, ILAC-MRA).

If your facility also provides accelerated outdoor weathering / UV degradation testing under ISO 4892, please list that as an optional line item. We look forward to your prompt response.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Copper Pipes Testing in Qatar

Enquiry:

One of the supplier delivered copper pipes to our ongoing project. Consultant instructed us to do the below testing.

The laboratory must sample the delivered batch and provide a conclusive report on:

*The chemical composition of the internal residue and its potential toxicity.

*The compatibility of this specific internal residue with a 50ppm chlorine disinfection process.

*The lab must have ISO/IEC 17025 Accreditation.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Performance Validation Testing in Sharjah, UAE

Enquiry:

we would like to have the performance of our system validated by an ISO 17025 accredited laboratory.

Our goal is to carry out a comprehensive analysis comparing untreated inlet water with treated outlet water. The parameters include microbiological, chemical, and physico-chemical testing in accordance with drinking water regulations and international standards.

I am currently located in Sharjah, UAE, until December 7, 2025, with the system to be tested, and I can arrange for samples to be taken on-site according to your specifications or provide them as needed.

Could you please send us a detailed quotation for such an analysis, including costs, timeframe, and the exact procedure?


One of our highly proficient and ISO certified laboratory would be taking over this job.