• Home
  • Archive by category "Chemical Analysis"

Coolant Sample Testing in Islamabad, Pakistan

Enquiry:
We are looking for a laboratory to perform testing and analysis of a coolant sample. Kindly provide us with your quotation for testing the following parameters:

  1. Boiling Point
  2. Freezing Point
  3. Mono Ethylene Glycol (MEG) Ratio / Concentration
  4. Anti-Rust Agent
  5. Anti-Scaling Agent

Please also include the following information in your quotation:

  • Test methods/standards used
  • Sample quantity required
  • Turnaround time for the test results
  • Cost breakdown (if applicable)
  • Any other requirements for sample submission

We would appreciate receiving your quotation at your earliest convenience.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

ACP Fire Rating Testing in UAE

Enquiry:

We require a proposal for fire rating testing of 1 no ACP panel to check whether ACP is fire rated or not.

Please address proposal to,

To: community management

Attention: ——


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Calcium Carbonate Powder Testing in Qatar

Enquiry:

Need to undergo physical and chemical properties laboratory test for calcium carbonate powder

Message:

Physical Properties:-

1.D50 and D97 Particle Size Analyser in microns through malvern particle analyser.

2.Brightness and Whiteness of material

3.Material Hardness

4.Specific Gravity/Density

5.Oil Absorption

6.Ph value of material

Chemical Properties:-

1.Tota Caco3 percentage for purity test


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

1-MCP Testing 1.3% in Solution Generate CoA in Wapato, WA

Enquiry:

It appears that your lab is able to perform accredited testing of 1-MCP samples and generate CoAs? We’re looking to have a liquid sample of 1-MCP, encapsulated with a-cyclodextrin at ~1.3wt% in a matrix of salt and water tested. Is this something you would be able to help us out with or could you offer guidance on where we could look?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Detergent Foam Performance Testing in Selangor, Malaysia

Enquiry:

We are manufacturer of specialty detergents for the semiconductor, electronics, and precision cleaning industries. Our facility is located at Berjaya Park, Shah Alam, Selangor, Malaysia.

We are currently looking for a laboratory or testing service provider that offers detergent foaming performance testing. We would appreciate it if you could provide information regarding:

  1. The foaming test methods available for detergent products.
  2. The testing standards or procedures used (e.g., ASTM, ISO, or other recognized methods).
  3. The sample quantity required for testing.
  4. The testing lead time.
  5. The applicable testing charges.

Kindly let us know the testing methodology that would be used to evaluate detergent foaming characteristics.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

VISCO Elastic Coating Testing in Iraq

Enquiry:

Further to our discussion, please kindly confirm the possibility and quote us the costs for carrying out below tests on VISCO Elastic Coating as per ISO-21089-3 -2016. We need itemized costs and prices for each so we negotiate with our client and get final approval.

itemTestStandard
1Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 28 days, Temperature: 23 °CISO-21809-3
2Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 28 days, Temperature: 80 °CISO-21809-3
3Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 48 hours , Temperature: 65 °CISO-21809-3
4Indentation Resistance ISO 21809-3 Annx E @ 23°CISO-21809-3
5Peel Adhesion ISO 21809-3, Annex H @ 23°C to steel and plant coatingISO-21809-3
6Indentation Resistance ISO 21809-3 Annx E @ 80°CISO-21809-3
7Peel Adhesion ISO 21809-3, Annex H @ 80°C to steel and plant coatingISO-21809-3

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

GCIR Emulsifier Performance Test in Dammam, KSA

Enquiry:

We would like to request your quotation for conducting performance testing and providing a complete formulation for an Oil-Based Mud (OBM) system as per the following specifications:

Scope of Work:

  • Conduct performance testing for GCIR secondary emulsifiers.
  • System to be based on:
  1. 80 pcf typical Barite
  2. OBM with Oil/Water Ratio (OWR) 80/20
  3. WPS approximately 250,000 mg/L

Deliverables:

  1. Final mud formulation.
  2. Detailed test results including:
  • Electrical Stability (ES)
  • Rheology at 150°F:
  • 600 rpm
  • 300 rpm
  • 6 rpm
  • 3 rpm
  • Plastic Viscosity (PV)
  • Yield Point (YP)
  • Gel Strength (10 sec / 10 min)
  • HTHP Filtration at 300°F:
  1. Filtrate volume
  2. Indication of any observed water
  • Test results to be provided:
  1. Before hot rolling
  2. After hot rolling for 16 hours at 300°F

Kindly include in your quotation:

  • Commercial offer with detailed pricing
  • Lead time for testing and report submission
  • Technical datasheets 
  • Validity of the quotation

We appreciate your prompt response and look forward to receiving your competitive offer.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

HDPU vs PVDF Coating Testing in Doha, Qatar

Enquiry:

HDPU vs PVDF Coating Testing (AAMA 2605)

Kindly confirm whether your laboratory

  1. Confirmation of your accreditation scope relevant to AAMA 2605
  2. Proposed testing program and methodology for comparative evaluation (PVDF vs. HDPU)
  3. Location of testing laboratory (Qatar or nearest regional facility)

The testing is required for a project in Qatar, and compliance with consultant and project specifications is mandatory.

We would appreciate your prompt response to proceed with the evaluation and approval process.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Fulvic Acid Cargo Contamination Testing in Egypt

Enquiry:

A cargo of Fulvic Acid (KFULVIC-AG) was exposed to fire and firefighting water. The consignee is claiming that the product has lost its chemical specifications. 

Accordingly, we would like to arrange laboratory testing on a cargo sample to verify the fulvic acid content and to confirm whether the acidity/alkalinity (pH) remains within specification.

The declared composition of the product is as follows:

Organic Matter: 75%

Humic Acid: 36%

Fulvic Acid: 13%

K₂O: 3.5%

Kindly advise what laboratory tests can be conducted to assess the product condition after exposure to fire, smoke, and water, and please provide your quotation for the required analyses.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].