Enquiry:

Further to our discussion, please kindly confirm the possibility and quote us the costs for carrying out below tests on VISCO Elastic Coating as per ISO-21089-3 -2016. We need itemized costs and prices for each so we negotiate with our client and get final approval.

itemTestStandard
1Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 28 days, Temperature: 23 °CISO-21809-3
2Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 28 days, Temperature: 80 °CISO-21809-3
3Cathodic Disbondment ISO 21809-3, Annex G Voltage: -1500 mV vs SCE Duration: 48 hours , Temperature: 65 °CISO-21809-3
4Indentation Resistance ISO 21809-3 Annx E @ 23°CISO-21809-3
5Peel Adhesion ISO 21809-3, Annex H @ 23°C to steel and plant coatingISO-21809-3
6Indentation Resistance ISO 21809-3 Annx E @ 80°CISO-21809-3
7Peel Adhesion ISO 21809-3, Annex H @ 80°C to steel and plant coatingISO-21809-3

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

GCIR Emulsifier Performance Test in Dammam, KSA

Enquiry:

We would like to request your quotation for conducting performance testing and providing a complete formulation for an Oil-Based Mud (OBM) system as per the following specifications:

Scope of Work:

  • Conduct performance testing for GCIR secondary emulsifiers.
  • System to be based on:
  1. 80 pcf typical Barite
  2. OBM with Oil/Water Ratio (OWR) 80/20
  3. WPS approximately 250,000 mg/L

Deliverables:

  1. Final mud formulation.
  2. Detailed test results including:
  • Electrical Stability (ES)
  • Rheology at 150°F:
  • 600 rpm
  • 300 rpm
  • 6 rpm
  • 3 rpm
  • Plastic Viscosity (PV)
  • Yield Point (YP)
  • Gel Strength (10 sec / 10 min)
  • HTHP Filtration at 300°F:
  1. Filtrate volume
  2. Indication of any observed water
  • Test results to be provided:
  1. Before hot rolling
  2. After hot rolling for 16 hours at 300°F

Kindly include in your quotation:

  • Commercial offer with detailed pricing
  • Lead time for testing and report submission
  • Technical datasheets 
  • Validity of the quotation

We appreciate your prompt response and look forward to receiving your competitive offer.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

HDPU vs PVDF Coating Testing in Doha, Qatar

Enquiry:

HDPU vs PVDF Coating Testing (AAMA 2605)

Kindly confirm whether your laboratory

  1. Confirmation of your accreditation scope relevant to AAMA 2605
  2. Proposed testing program and methodology for comparative evaluation (PVDF vs. HDPU)
  3. Location of testing laboratory (Qatar or nearest regional facility)

The testing is required for a project in Qatar, and compliance with consultant and project specifications is mandatory.

We would appreciate your prompt response to proceed with the evaluation and approval process.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Fulvic Acid Cargo Contamination Testing in Egypt

Enquiry:

A cargo of Fulvic Acid (KFULVIC-AG) was exposed to fire and firefighting water. The consignee is claiming that the product has lost its chemical specifications. 

Accordingly, we would like to arrange laboratory testing on a cargo sample to verify the fulvic acid content and to confirm whether the acidity/alkalinity (pH) remains within specification.

The declared composition of the product is as follows:

Organic Matter: 75%

Humic Acid: 36%

Fulvic Acid: 13%

K₂O: 3.5%

Kindly advise what laboratory tests can be conducted to assess the product condition after exposure to fire, smoke, and water, and please provide your quotation for the required analyses.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Compatibility Testing HDPE Grade Chemicals, UAE

Enquiry:

We require compatibility testing for our HDPE grades with the specified liquid grade chemicals.

Please conduct the necessary tests to determine whether our HDPE material is compatible and suitable for use with these chemicals. One of the grades is in liquid form; therefore, ensure appropriate testing conditions are applied.

Kindly coordinate with our Quality Manager regarding sample collection and test requirements. Please issue the complete test report to us upon completion


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Assay test for Geleol mono, diglycerides in RAK, UAE

Enquiry:

I am writing to inquire whether your laboratory can perform an Assay test for Geleol mono- and diglycerides using size‑exclusion chromatography (SEC) with the following parameters:

  • Stationary phase: Styrene–divinylbenzene copolymer R (5 μm) with 10 nm pore size
  • Detector: Differential refractometer
  • Applicable standards: USP/EP assay for mono‑ and diglycerides

Due to unavailability of this analytical setup in our facility, we are seeking outsourcing options within the UAE, Middle East, or India.

Kindly confirm:

  1. Whether your laboratory can perform this test.
  2. Expected turnaround time and cost.
  3. Any sample quantity requirements or method suitability considerations.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Failure analysis of coating/NACE TM0174 in KSA

Enquiry:

Kindly provide your best quotation for the following scope of work:

Scope of Work:

  • Failure Analysis of Coating in accordance with NACE TM0174 – Laboratory Test Methods for Evaluating Protective Coatings and Lining Materials on Metallic Substrates in Immersion Service.

If you have any questions or require further clarification, please do not hesitate to reach out.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Salt and Sodium Hypochlorite Testing in Oman

Enquiry:

I request you to please send me the quotation for the below requested items:

SR.NOSample  NameQuantity
1Salt

Purity: 99.6%
Special tests required: Bromate and Bromine content
1
2Sodium Hypochlorite

Concentrations: 10% and 15%
Special tests required: Bromate and Bromine content
1

If you have any questions or require any further clarification, please don’t hesitate to contact me.

I would appreciate it if you could share the quotation before  02-10-2025 @ 1pm


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chemical and Mechanical Testing in Sohar, Oman

Enquiry:

Please send us your offer for the following materials Lab testing.

1. Lab Test – Chemical analysis of steel plate 40mm thk x 300×300 mm as per SA 537 CL.1 – 1 No.

2. Lab Test –Mechanical test steel plate 40mm thk x 300×300 mm as per SA 537 CL.1 – 1 No.

    (a. Impact test @-38 deg c        b. Vicker Hardness       c. Tensile Test)


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Testing of Polyethylene Film in Qatar

Enquiry:

I want to test 2 samples of Polyethylene film (130 microns) in both in the Machine and Transverse directions for the following tests:

2a) Tensile strength (MPa) and elongation (%) at break, according to the test method standard ISO 527 1-3.

2b) Tensile strength at Yield (MPa), as per the test method standard ISO 527 1-3.

2c) 2% Secant modulus, following the test method standard ASTM D 882 (Method A).

Do you have facility of above mentioned testing?


One of our highly proficient and ISO certified laboratory would be taking over this job.