• Home
  • Archive by category "Environmental Testing"

Environmental Testing in Malta, Europe

Enquiry:

We often have jobs requiring monitoring of land, waste, groundwater and air, where we take the samples and send them to an ISO 17025-certified lab for analysis.  A list of a typical analytical suit is detailed on the below tables:

Bulk testing:

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
Total petroleum hydrocarbons: C10-C40GC-FIDIn-house method0.1 – 10 mg/kgYes (soil)
Total Organic CarbonTitrationIn-house method based on BS 1377<0.1%Yes (Soil)
BTEXGC-MS (Headspace)In-house method based on EPA Method 8260, Revision B<1 μg/kgYes (Soil)
PAHsGC-MSIn-house method based on EPA Method 8270, Revision C0.01 ug/kgYes (Soil)
PCBsGC-MSIn-house method based on EPA Method 8082;
EPA Method 1668
7 μg/kgYes (Soil)
MetalsICP-OESIn-house method based on BS 1377All <1 mg/kg    Yes (Soil)
TBTGC-MSIn-house method0.01 mg/kgNo
AsbestosPolarised light microscopyHSG248Presence / absence; if asbestos is detected the quantification test has a LoD of 0.001%Yes
MoistureGravimetryn/a0.1%No

Waste characterisation testing

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
Acid neutralising capacity
(pH 4, pH 7)
TitrationEA NEN 7371:2004(+/-) mol/kgNo
Loss on ignitionGravimetryIn-house method based on BS 1377:19900.01%No
pHProbeBS 1377No

Leachability testing

AnalyteAnalytical methodologyReference standardLimit of detectionTest-specific accreditation
As (dissolved)ICP-OES (Filtered)In-house method based on BS 1377<1.0 µg/kgYes
Ba (dissolved)<0.05 µg/kg
Cd (dissolved)<0.1 µg/kg
Cr (dissolved)<0.4 µg/kg
Cu (dissolved)<0.3 µg/kg
Hg (dissolved)<0.5 µg/kg
Mo (dissolved)<0.4 µg/kg
Ni (dissolved)<0.3 µg/kg
Pb (dissolved)<1 µg/kg
Sb (dissolved)<1.7 µg/kg
Se (dissolved)<4 µg/kg
Zn (dissolved)<0.4 µg/kg
Total dissolved solidsGravimetryIn house method based on PN-EN 27888:19994 mg/LYes
Phenols (total-mono)ColorimetryIn house method10 µg/LYes
Dissolved organic carbonTOC Analysern/a0.1 mg/LNo
ChlorideDiscrete analyserIn house method0.15 mg/LYes
FluorideDiscrete analyserIn house method0.05 mg/LYes
SulphateDiscrete analyserIn-house method0.03 mg/LYes

Could you kindly let us know if you are able to provide some or all of the attached analytical services, and send us a copy of your ISO 17025 / test-specific certification if so?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Swab Test, AAQM, Water Analysis in KSA

Enquiry:

We are local manufacturer producing Tin cans and Plastic bottles for packaging.

Could you please advise whether you can perform the following tests which required to meet our BRC Standard for packaging:

Micro Biological Tests:

  1. Swab Collection and Microbiological Testing From Workers Uniform and Finished products. (Tests: Salmonella, Coliforms, Aerobic Plate Count, Escherichia Coli, Yeast & Mould).
  2. Bacteriological Tests for Municipal and Process water ( Total Coli form, Total Bacterial Count).

Chemical Tests:

  1. Analysis of Process water (pH, TDS, Fe, NO2,)
  2. Migration test for plastic bottle.
  3. Compressor air quality (Tests: Cabon Dioxide, Hydrocarbon, Moisture, Oxygen, Carbon Monoxide and Oduor).
  4.  

Environmental Tests:

Air quality  (Suspended Particulates Matter in Ambiant Air at production area, PM10). This should include respirable (inhalable) and non-respirable particulates matters (PM10) as well as total suspended particulates matters (SPM) calculated for 8 and 24 hours.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Indoor Air Quality Testing in Fujairah

Enquiry:

We are looking to get an indoor air quality test done for our place in Fujairah.

Can you send me the requirements to do a quotation for this.

If a site visit is required a 7-day negative PCR test is required for access.

Please let me know so I can make the necessary arrangements.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Environmental Testing in Jordan

Enquiry:

We would like to conduct the below tests at our facilities located in Jordan.

TSP according to OSHA Instructions TED -1-00-015 @ 25 points.

PM10 according to OSHA Instructions TED -1-00-015 @ 48 points.

PM2.5 according to OSHA Instructions TED -1-00-015 @ 23 points.

SO2 using electro chemical cells @ 23 points.  

NO2 using electro chemical cells @ 23 points.

CO using electro chemical cells @ 23 points.

CO2 using NDIR @ 23 points.

O2 using electro chemical cells @ 23 points.

TVOCs using Fuel Cell sensors @ 30 points.

O3 using NDIR @ 23 points.

Kindly issue the quotes accordingly.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Environmental Testing of Hotel in Qatar

Enquiry:

We are looking for a company who will Inspect the AC, walls, ceilings, etc. to determine if there is any mold growth or any other health concerns. Test samples will be collected and analyzed for any locations that have visible mold growth. Air quality sampling will be collected from the Living Room, Bathroom, Kitchen, and Bedroom of each unit. ACGIH Guidelines for the assessment of Bioaerosols 35/1989 will be used to determine if Mold, Bacterial count of yeast exceeds limits. A total of 15 Apartments will be tested. Apartments are 45sqm each. ***

This is a onetime performance to be accomplished within 15 days after the award.

Please review attached documents and provide your formal proposal by populating the attached pricing schedule no later than.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chimney Emission Testing in UAE

Enquiry:

According to Dubai Municipality Requirements kindly quote us the best offer for testing:

  1. Waste Water.
  2. Chimney Emissions.
  3. LPG Storage Tank.
ActionSampleParameters
Chemical Tests as per Dubai Municipality RequirementsChimney EmissionsCarbone Dioxide, Carbon Monoxide, ISO Kinetic Sampling Rate, Oxides of Nitrogen NOx, Oxygen %, Stack Gas Volumetric Rate, Stack Gas Temperature, Stack Gas Velocity, Sulphur Dioxide, Total Suspended Particles, TVOC (Total Volatile Organic Chemical Level), Stack Static Pressure, Ambient Temperature
Chemical & Microbiological Tests as per Dubai Municipality RequirementsWaste WaterAluminum(Al), Arsenic(As), Cadmium(Cd), Chromium(Cr), Cobalt(Co), Copper(Cr), Iron(Fe), Lead(Pb), Manganese(Mn), Mercury(Hg), Nickle(Ni), PH(25C°), Selenium(Se), Silver(Ag), Total Dissolved Solids(TDS), Total Heavy Metals, Total Suspended Solids(TSS), Zinc(Zn), Biochemical Oxygen Demand(BOD), Chemical Oxygen Demand(COD), Nitrogen(Ammoniacal), Oil & Grease Emulsified, Free Oil-Oil & Grease, Total Sulfate, Sulfides

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requsites, do drop us email and we shall revert instantly -> [email protected].

Environmental Testing Multiple Projects in Oman

Enquiry:

We wish to introduce you to our company, a leading environmental, technical and sustainability consultancy & services company based in Muscat. We offer the following services:

• Environmental Impact Assessment (EIA)

• Waste Management

• Environmental Training

• Environmental Monitoring

• Environmental Legislation & Regulation Review

• Water & Wastewater Treatment Design, Operation & Maintenance

• Sustainable Development Solutions .

•QHSE Management & IMS Systems.

• Solar Systems design & Installation.

We are developing our business related to Wastewater & Sewage Design, Operation & Maintenance  and we are looking for an international company to have a joint venture/partnership to work with and provide us with technical support and wastewater & sewage management equipment for projects in Oman ranging from small villas installations to large Waste water/Sewage Plants (8 m³ to over 12000 m³).

Your feedback is highly appreciated as we are in the process of preparing to participate in a number of wastewater & sewage Projects in Oman.


One of our highly proficient team of Environmental experts with PHD heads, would be taking over these projects.

Odour Sampilng and Monitoring in KSA

Enquiry:

We are interested in contact with a company expert in odour sampling and monitoring according to standard codes in order to analyze the impact of the construction of some facilities in Saudi Arabia. One of these facilities is a sewage treatment plant that it is under construction now.

We would highly appreciate if you could give a contact to further discuss the project.


One of our highly capable and certified laboratory would be taking over this project.