• Home
  • Archive by category "Oman"

Transformer Oil DGA, Oil filtration Test in Oman

Enquiry:

Please request a competitive offer for the For Transformer Oil DGA Analysis & Oil Filtration in power Plan.

Your immediate response will be appreciated and please feel free to contact me for clarification on this matter.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Treated Sewage Water Testing in Oman

Enquiry:

I am from Oman, I saw in your website that you have labs in Oman.

I need to test a treated sewage water against the below components, in order to use the water or not for agriculture applications: 

  1. Biochemical Oxygen Demand
  2. Chemical Oxygen Demand
  3. Total Suspended Solids
  4. Conductivity
  5. Sodium Absorption Ratio
  6. pH Value
  7. Aluminum
  8. Arsenic
  9. Barium
  10. Boron
  11. Beryllium
  12. Cadmium
  13. Chlorides
  14. Chromium
  15. Cobalt
  16. Copper
  17. Cyanides
  18. Fluorides
  19. Iron
  20. Lead
  21. Lithium
  22. Magnesium
  23. Manganese
  24. Mercury
  25. Molybdenum
  26. Nickel

27. Nitrate, Nitrogen (Ammonia) and Organic Nitrogen

28. Oil and Grease 

 29. Total Phenols 

  • Total Phosphorous 
    • Selenium
    • Sodium
    • Sulphate
    • Silver
    • Sulphides
    • Vanadium
    • Zinc
    • Fecal Coliforms
    • Viable Nematode

or any other extra parameters and analysis you run.

Where is your lab to deliver the sample?

What is the minimum quantity for the sample?

What will be the price?


Lube Oil and Control Oil Testing Tender, Oman

Enquiry:

We would like to invite you to participate in the tendering process for the subjected tender. 

Please find attached a detailed tender package and submit your best competitive proposal latest by the tender closing date, 14–August-2022, to Offices as per SOW/RFP requirements on or before 14:00PM (Oman Time).  

Item Parameter Warning Level (Standard reference) SEIMENS GTG 800 SEIMENS STG 300 Control Oil STG300 1 Water content ASTM D6304, ISO760 1 1 1 2 Solid Impurity – Sediment ASTMD-4898 M 1 1 1 3 Solid impurities- Oil cleanliness ISO 4406 and NAS1638 1 1 1 4 Viscosity @40C ASTM D445 or D7279, ISO 3104 1 1 1 5 Chemical elementwear metal element condition (report in decimal tenths digit) (ICP-AES, ASTMD5185, ASTM D6595) (RDE fine wear metal18 elements and RFS coarse wear metal 11 elements) 1 1 1 6 Chemical ElementContaminants (ICP-AES, ASTM D5185, ASTM D6595) 1 1 1 7 Chemical element additive (ICP-AES, ASTM D5185, ASTM D6595) 1 1 1 8 Total Acid Number (TAN) (ASTM D974, D664, ISO 6618) 1 1 1 9 Air Release at 50˚C (ASTM D3427, ISO 9120) 1 1 1 Item Parameter Warning Level (Standard reference) SEIMENS GTG 800 SEIMENS STG 300 Control Oil STG300 1 Water content ASTM D6304, ISO760 1 1 1 2 Solid Impurity – Sediment ASTMD-4898 M 1 1 1 3 Solid impurities- Oil cleanliness ISO 4406 and NAS1638 1 1 1 4 Viscosity @40C ASTM D445 or D7279, ISO 3104 1 1 1 5 Chemical elementwear metal element condition (report in decimal tenths digit) (ICP-AES, ASTMD5185, ASTM D6595) (RDE fine wear metal18 elements and RFS coarse wear metal 11 elements) 1 1 1 6 Chemical ElementContaminants (ICP-AES, ASTM D5185, ASTM D6595) 1 1 1 7 Chemical element additive (ICP-AES, ASTM D5185, ASTM D6595) 1 1 1 8 Total Acid Number (TAN) (ASTM D974, D664, ISO 6618) 1 1 1 9 Air Release at 50˚C (ASTM D3427, ISO 9120) 1 1 1 10 Foaming Sequence I-III ASTM D892, ISO 6247 1 1 1 11 Demulsibility ASTM D1401, ISO 6614 1 1 1 12 Oxidation Stability RPVOT, ASTM D2272 1 1 1 13 RULER (Remaining Useful Life Evaluation Routine) <25 1 1 1 14 VPI TM (Vanish Potential Index) >35 1 1 1 15 SPITM (Sludge Potential Index) >35 1 1 1 16 Oxidation by Product Content VsPI (MPC) (CIE-Lab d_E), ASTM D7843) 1 1 1 17 Oil Condition: Oxidation Nitration FTIR, ASTM E2412M 1 1 1 18 % Phenolic Additive FTIR, ASTM D2668 1 1 1 19 Flash Point ASTM D3828 1 1 1 20 Rust Prevention ASTM D665-A 1 1 1


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing Tender, Oman

Enquiry:

We would like to invite you to participate in the tendering process for the subjected tender. 

Please find attached a detailed tender package and submit your best competitive proposal latest by the tender closing date, 14–August-2022, to Offices as per SOW/RFP requirements on or before 14:00PM (Oman Time).  

The table below indicate all parameters analysist.

S. No. Parameter Warning Level (Standard
reference)
Times
1 O2 (Oxygen) ASTMD3612 38
2 N2 (Nitrogen) ASTMD3612 38
3 CO2 (Carbon dioxide) ASTMD3612 38
4 CO (Carbon monoxide) ASTMD3612 38
5 H2 (Hydrogen) ASTMD3612 38
6 CH4 (Methane) ASTMD3612 38
7 C2H2 (Acetylene) ASTMD3612 38
8 C2H4 (Ethylene) ASTMD3612 38
9 C2H6 (Ethane) ASTMD3612 38
10 C3H6 (Propylene) ASTMD3612 38
11 C3H8 (Propane) ASTMD3612 38
12 DIELECTRIC
DISSIPATION FACTOR
ASTM D1816 gap1 3

13 RESISTIVITY OF
INSULATING OIL
ASTM D1169 38
14 ACID CONTENT OF
INSULATING OIL (BY
NEUTRALISATION)
ASTM D974 38
15 WATER CONTENT ASTM D1533 62
16 DIELECTRIC STRENGTH
OF INSULATING OIL
ASTM D149 62


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Microbiological Testing of Water, Oman

Enquiry:

I am looking to get a water quality certificate according to the bellow Parameters. Kindly let me know if this service is available with you. Feel free to contact me for further discussion  

 CLRW
Maximum microbial content (CFU/ml)10
Minimum resistivity (megohm-cm)10 (in-Line)
Particulate matter0.22 um filter

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Water Testing in Hyma Oman

Enquiry:

I am looking at how it would be possible to have a land (seismic) crews potable water tested. The sample would be taken from 4 different points around our camp.

Presently the camp is 1.5 hours driving time (in – out from the desert) from a town called Haima / Hayma.  Distance / Drive time from Muscat is 523Km/6Hrs.

Would you have any facility within this region where we could feasibly get water testing completed.


One of our certified and competent laboratory in Oman would be taking over this project.

Environmental Testing Multiple Projects in Oman

Enquiry:

We wish to introduce you to our company, a leading environmental, technical and sustainability consultancy & services company based in Muscat. We offer the following services:

• Environmental Impact Assessment (EIA)

• Waste Management

• Environmental Training

• Environmental Monitoring

• Environmental Legislation & Regulation Review

• Water & Wastewater Treatment Design, Operation & Maintenance

• Sustainable Development Solutions .

•QHSE Management & IMS Systems.

• Solar Systems design & Installation.

We are developing our business related to Wastewater & Sewage Design, Operation & Maintenance  and we are looking for an international company to have a joint venture/partnership to work with and provide us with technical support and wastewater & sewage management equipment for projects in Oman ranging from small villas installations to large Waste water/Sewage Plants (8 m³ to over 12000 m³).

Your feedback is highly appreciated as we are in the process of preparing to participate in a number of wastewater & sewage Projects in Oman.


One of our highly proficient team of Environmental experts with PHD heads, would be taking over these projects.

Bio Diesel Fuel Testing in Oman

Enquiry:


Please be informed that our students have prepared bio diesel fuel from date seed oil and almond oil as academic project.

We are looking for following diesel fuel test for our prepared Bio diesel fuel.

Diesel analysis as per Gulf standard

1.Color

2.Flash point

3.Density

4.Kinematic viscosity

5.Cetane Index

6.Calorific value

7.FT-IR analysis

Hence, I Kindly request you to provide your best price for the above test as earlier as possible to proceed further.


One of our highly proficient and ISO certified labortory in Oman would be taking over this job.