• Home
  • Archive by category "Qatar"

Frozen Shrimp Testing in Qatar

Enquiry:

Please send us your quotation for the testing of our Frozen Shrimp in Qatar.

Below are the complete product description and test parameters for your reference, please do advise the collection charges as per the given collection address.

Description:

                Item No. 1 – Farm Raised IQF Frozen White Shrimp HLSO Ez Peel 16-20/lb

                Item No. 2 – Farm Raised IQF Frozen White Shrimp HLSO Ez Peel 21-25/lb

                Item No. 3 – Farm Raised IQF Frozen White Shrimp HLSO Ez Peel 31-35/lb

                Item No. 4 – Farm Raised IQF Frozen White Shrimp PD Tail On 21-25/lb

                Item No. 5 – Farm Raised IQF Frozen White Shrimp PD Tail Off 41-50/lb

Test Parameters:

1.       – Organoleptic

2.       – Volatile basic nitrogen (TVB-N)


One of our ISO certified and competent lab for seafood and non-seafood testing would be carrying out this analysis.

Oily Water Testing in Qatar

Enquiry:

With reference to subject inquiry, we request you to submit your competitive offer for the scope defined below.


Scope of Work

  1. Oily Water Sample Analysis – 2 samples

Parameters to be analysed

S.NoDescription
1Temperature
2Color
3PH
4Electrical Conductivity
5TDS
6Caustic-Alkalinity
7BOD (5Days)
8COD (Oil Layer)
9COD (Water layer)
10BOD (Oil Layer)
11BOD (Water layer)
12Oil & Grease ( oily layer )  
13Oil & Grease (water layer )
14Total SS
15Chloride(as Cl)
16Sulphate(as SO4)
17Sulphide(as Sulphur)
18Cynide(as CN)
19Detergent(LAS as MBAS)
20Grease & Oil (Total)
21Grease & Oil (Hydrocarbon)
22Grease & Oil (Non-Hydrocarbon)
23Arsenic(as As)
24Barium(as Ba)
25Tin(as Sn)
26Iron(as Fe)
27Beryllium(as Be)
28Boron(as B)
29Manganese(as Mn)
30Phenolic compounds
31Fluoride(as F)
32Cadmium(as Cd)
33Chromium(as Cr), (Trivalent and Hexavalent)
34Copper(as Cu)
35Lead(as Pb)
36Mercury(as Hg)
37Nickel(as Ni)
38Selenium(as Se)
39Silver(as Ag)
40Zinc(as Zn)
41Metals in Total
42Chlorine(as Cl2)
43Phosphate(as PO4)
44Calcium(as Ca)
45Magnesium(as Mg)
46Nitrate(as NO3)
47Sulfide         
48Phenol  

One of our ISO certified laboratory would be conductin this oil mixed water testing.

Lube Oil Testing in Doha, Qatar

Enquiry:

We would like to request a quotation for oil analysis with categories as follows:

Item #CategoryTestQty
1Fluid propertiesViscosity, acid/base number, elemental analysis1 lumpsum
2ContaminationParticle counts, moisture analysis, elemental analysis
3Wear DebrisElemental Analysis

If you have clarification please don’t hesitate to contact me to clear any of your inquiries.


One of our ISO certified and accredited laboratory in Qatar would be dealing with this analysis.

Oil Quality Test for Petroleum Company, Doha

Enquiry:

Please note that we would like to know if the analysis facility for Oil Quality is available in your laboratory for the below listed parameters, as we need to know the price of each test as under :

  1. Membrane Patch Colorimetry ( MPC Varnish ).
  2. Oil Cleanliness.
  3. Ruler test.

One of our ISO certified and accredited lab in Qatar would be taking over this job.

Contract Water Testing in Qatar

Enquiry:

Please find the following table for your kind consideration. Kindly quote us your best price with a delivery date for the following.

See attached specs

  1. Comprehensive contract for water quality test including chemical supply

Please provide the following terms and conditions:

  • Quotation to be valid for 90 days.
  • The delivery period to be mentioned.

FOLLOWING AREA’S ANDNUMBER OF TEST POINTS ARE:
A. HOSPITAL BUILDING – WATER TESTING AND RECOMMENDATIONS AS FOLLOWS:
(TOTAL OF 136 TEST POINTS)

  1. MONTHLY AND QUARTERLY TEST
    • LEGIONELLA = 73 points
    • PSEUDOMONAS = 29 points
    • E. COLI / TOTAL COLIFORM = 4 points
    • AND DOMESTIC WATER CHEMICAL TEST = 4 POINTS
  2. QUARTERLY TEST
    • TBC = 29 points
    • HETEROTROPHIC PLATE COUNT (HPC). = 1 point
    B. SERVICE BUILDING – MONTHLY WATER TESTING WITH RECOMMENDATIONS
    INCLUDING SUPPLY ANDDELIVERY OF RECOMMENDED CHEMICAL ( TOTAL OF 9
    TEST POINTS):

• STEAM BOILER
• HOT WATER (HEAT EXCHANGER) CHEMICALS
NOTE:
LEGIONELLA – 1 SAMPLE POINT IS EQUAL TO 1 LITER VOLUME OF SAMPLE
PSEUDOMONAS – 1 SAMPLE POINT IS EQUAL TO 500 ML. VOLUME OF SAMPLE
C. SAMPLING BOTTLES AND PPE’S SHOULD BE SUPPLY BY THE CONTRACTOR.
D. WATER SAMPLE COLLECTED SHOULD BE SENT TO LABORATORY AFTER 2 HOURS
FROM TIME OF COLLECTION FOR TESTING.
E. LABORATORY TESTING COMPANY SHOULD BE APPROVED BY MOPH FOR TESTING
OF LEGIONELLA AND PSEUDOMONA

One of our ISO certified lab would be taking over this contract as per Muncipality specifications & ISO standards.

Contract Transformer Oil Testing in Qatar

Enquiry:

With reference to subject inquiry, we request you to submit your competitive offer for the scope defined below.


Scope of Work

  1. Transformer Oil Analysis – 8 samples

Below detailed parameters to be analysed for the sample oil.

Oil Analysis of transformers
Sl.NoDescription of parameters to be testedRemarks
 ADissolved Gas Analysis 
1Hydrogen
(H2) ( ppm)
 
2Methane (CH4)
(ppm)
 
3Ethane (C2H6) (ppm) 
4Ethylene (C2H4)(ppm) 
5Acetylene (C2H2)
(ppm)
 
6Carbon monoxide
(CO) (ppm)
 
7Carbon dioxide
(CO2) (ppm)
 
8Nitrogen (N2) (ppm) 
9Oxygen (O2) (ppm) 
10TDCG (ppm) 
11Rate change per day 
12Rate change per year 
 BOil Quality Analysis 
13Sample temp.
(°C)
 
14Moisture ( ppm) 
15Moisture
corrected
to 20(°C)
 
16% Saturation 
17% Saturation
Interfacial
Tension (mN/m)
 
18Acidity
(mgKOH/g)
 
19Colour number 
20Visual 
21Dielectric BDV
(kV)
 
22Power factor %
@
25°C
 
23Power factor %
@
90°C
 
24Specific Gravity 
25Viscosity 
26Sediment &
sludge
 
27Density 
28Particles 
29PCB 
30Corrosive
Sulphur
 
31DBDS 
Furan Analysis 
325-hydroxy-methyl-
2-furfuraldehyde (5HMF)
(ppm)
 
332-furfuraldehyde (2FAL)
(ppm)
 
342-Acetylfuran (2ACF)
(ppm)
 
355-methyl-
2-furfuraldehyde (5MEF)
(ppm)
 
362-fufuryl Alcohol (2FOL)
(ppm
 

Note: :

–          Sample to be Collected at Site

–          Containers for collecting the sample to be provided by the contractor

–          Detailed reports shall be produced within 7 – 10 days of the collection

–          Any recommendation or report shall be advised on the oil analysis.

–          Any Parameter is not feasible or you can recommend for alternative as per Transformer maker recommendations

S NoSubstation NameTransformer NumberHzTransformer Rating VoltageTypeRemarks
1Substation – Transformer – 150Hz50/60 MVA132/11 KVOil 
2Transformer – 250Hz50/60 MVA132/11 KVOil 
3Substation – Transformer – 150Hz900W415/30VOil 
4Transformer – 250Hz3200W415/40VOil
5Transformer – 350Hz3200W415/40VOil 
6Transformer – 450Hz2700W415/30VOil 
7Transformer – 550Hz2700W415/30VOil 
8Transformer – 650Hz2700W415/30VOil 

One of our highly capable and competent lab will be taking over this contract.

Restaurant Foods Testing in Qatar

I’m writing this email in connection with obtaining some information regarding the Determination Food Nutrient Content of our Restaurant Foods (multiple items) .

We are planning to determine the Nutritive Facts for our restaurant food items.

Please find the Details relevant for you to start the Process.

Please send your quotation regarding the Analysis as per our specification.

One of our best accredited and ISO certified lab would be taking over this food testing project.