Third Party Type Testing of HDPE DWC Pipe in Dubai, UAE

Enquiry:

We require a quotation for conducting Third-Party Type Testing of HDPE Double Wall Corrugated (DWC) Pipe, Size 40 mm OD / 32 mm ID, in accordance with IEC 61386-24.

Please provide your quotation for the following tests:

  1. Dimensional Verification (OD, ID, Wall Thickness)
  2. Compression Test
  3. Impact Resistance Test
  4. Bending Test at Room Temperature
  5. Bending Test at -5°C
  6. Resistance to Flame Propagation Test
  7. Glow Wire Test (750°C)
  8. IP67 Dust Ingress Test
  9. IP67 Water Ingress Test
  10. Anti-Rodent Test
  11. UV Resistance / UV Protection Test
  12. Raw Material Verification (Density & MFR/MFI)

Kindly provide:

  • Test charges
  • Sample quantity requirement
  • Lead time for testing
  • Accreditation details of the laboratory
  • Format of the Type Test Report

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Fire Foam Concentrate Testing NFPA-11 in Dubai, UAE

Enquiry:

We require the analysis of four (4) samples of firefighting foam concentrate to verify their suitability in accordance with NFPA 11 requirements (or equivalent). The scope of testing includes the following:

  • Visual Appearance (color, sediments, phase separation) – Verification of color, homogeneity, presence of sediments, contamination, or phase separation.
  • pH – Measurement of the acidity/alkalinity of the foam concentrate to identify potential chemical degradation.
  • Density / Specific Gravity.
  • Viscosity.
  • Foam Expansion Ratio – Evaluation of the foam generation capability. The test compares the volume of foam produced with the volume of foam solution used to generate it (Expansion Ratio = Foam Volume / Foam Solution Volume).
  • Drainage Time (e.g. 25% drainage time) – Measurement of the time required for 25% of the liquid contained in the foam blanket to drain out. Longer drainage times generally indicate more stable foam.
  • Foam Stability – Assessment of the ability of the foam blanket to maintain its structure over time without rapid collapse.
  • Surface Tension.

Could you please confirm whether the above (or equivalent) is within your scope. If so, please let us know minimum volume for each foam concentrate samples and provide a quotation addressed as follows:


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Fuel Storage Tank Calibration in Sharjah, UAE

Enquiry:

We would like to invite your quotation for the calibration of an existing fuel storage tank located at our site in Sharjah, UAE.

Tank Details:

• Tank Type: Fuel Storage Tank

• Capacity: 16,000 Imperial Gallons

• Location: Sharjah, UAE

Scope of Work:

Site visit and calibration of the fuel storage tank.

Preparation of tank calibration chart/table indicating volume versus dip level.

Issuance of calibration certificate and complete calibration report.

Provision of all equipment, tools, manpower, and consumables required to perform the calibration.

Submission of soft and hard copies of all calibration documents upon completion.

Kindly include the following information in your quotation:

• Calibration methodology to be adopted.

• Lead time for mobilization and completion.

• Validity of quotation.

• Payment terms.

• Any site requirements or prerequisites from our side.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Third-party Certification for Diesel Tank in UAE

Enquiry:

We are currently undertaking a Job on Hand project and would like to request your quotation, in accordance with the project requirements for:

Project
DescriptionUnitQty 
Third Party Certification for diesel tankNos1 

We would appreciate receiving your quotation at your earliest.

Should you require any additional information or clarification, please do not hesitate to contact the undersigned.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Physiochemical Testing of Water in Fujairah, UAE

Enquiry:

I have approximately 25 samples of water, to test for Physio- chemical

analysis- Ph, TDS, Turbidity, DO, Chemical constituents.

This is for educational purposes. Can you please provide a quote for the service?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].