Generator Used Oil Testing in Dubai, UAE

Enquiry:

Please quote us your charges for testing of generator used oil.

Used generator used oil / Engine Oil

S. NoParameterTest MethodRate per sample in AED
1Kinematic Viscosity at 100 deg CASTM D 445       
2Total Base NumberASTM D 2896
3Flash PointASTM D 92
4Water contentASTM D 95
5Pentane InsolublesASTM D 893
6Wear Metals and Additives Metals Sodium Iron Chromium Nickel Silicon Aluminium Lead Copper Tin Potassium Boron Calcium Zinc Phosphorus Magnesium MolybdenumASTM D 5185
7SootSootmeter
8GlycolASTM E 2412
9Sulphation  ASTM D 7414
10Nitration
11Fuel Dilution
Optional Test   
1Analytical FerrographyASTM D 7690

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

AFFF, Ground Water and Oil Water Testing in Dubai, UAE

Enquiry:

Request you to provide the AFFF Foam quotation for 6 samples.

Furthermore please provide your best rate for the following requirement:

  • Groundwater samples – 30 Qty.
  • Oily water samples (For disposal)  – 20 Qty.

The parameters for both are provided in the attached pdf file.

GROUNDWATER

BACTERIOLOGICAL PARAMETERS

Sl#Test DescriptionTest MethodPQL
1Escherichia Coli,cfu/100mLAPHA 9222D/9225D1
2Total Coliforms,cfu/100mLAPHA 9222 B1.0
3Total Aerobic Bacteria (as TPC, TAB, HPC),cfu/mLAPHA 9215 B1.0

CHEMICAL PARAMETERS

Sl#Test DescriptionTest MethodPQL
1Chlorine (Residual),mg/LAPHA 4500 Cl G0.1
2Oil and Grease,mg/LAPHA 5520 B1.3
3Sulfates,mg/LAPHA 4110 B0.03
4Total Dissolved Solids dried @ 180° C,mg/LAPHA 2540 C5
5Total Hardness as CaCO3,mg/LAPHA 2340 B (Hardness Calc.)0.5
6Total Nitrogen,mg/LAPHA 4500 N C1.0
7Chlorides,mg/LAPHA 4500 Cl¯ B1.0
8Biochemical Oxygen Demand,mg/LAPHA 5210 B2
9Cyanides,mg/LAPHA 4500 CN¯ C0.01
10Nitrogen Nitrates,mg/LAPHA 4500 NO3¯ B0.01
11Phenols,mg/LAPHA 5530 C&D0.1
12Total Sulfides,mg/LAPHA 4500 S²¯ F1.6
13Phosphates,mg/LAPHA 4500 P E0.03
Sl#Test DescriptionTest MethodPQL
1BTEXNUS EPA SW 846/8260B4.1-7.8, µg/L
2TOTAL PETROLEUM HYDROCARBONSUS EPA SW-846/8015B50-100 µg/L

PHYSICAL PARAMETERS

Sl#Test DescriptionTest MethodPQL
1Conductivity,mS/cmAPHA 2510 B0.1
2Temperature,° CAPHA 2550 B0.1
3Turbidity,NTUAPHA 2130 B1
4pH Value,APHA 4500 H+B0.1
5Dissolved Oxygen,mg/LAPHA 4500 O C0.1
6Color,unitAPHA 2120 C1.0

METALS ICP

 Sl#Test DescriptionTest MethodPQL
 1Aluminum,mg/LUS EPA SW 846/6010 B0.2
 2Arsenic,µg/LUS EPA SW 846/6010 B0.5
 3Barium,mg/LUS EPA SW 846/6010 B0.05
4Cadmium,mg/LUS EPA SW 846/6010 B0.07 
5Calcium,mg/LUS EPA SW 846/60100.02 
6Chromium,mg/LUS EPA SW 846/6010 B0.068 
7Cobalt,mg/LUS EPA SW 846/6010 B0.066 
8Copper,mg/LUS EPA SW 846/6010 B0.07 
9Iron,mg/LUS EPA SW 846/6010 B0.5 
10Lead,mg/LUS EPA SW 846/6010 B0.09 
11Magnesium,mg/LUS EPA SW 846/6010 B0.01 
12Manganese,mg/LUS EPA SW 846/6010 B0.03 
13Potassium,mg/LUS EPA SW 846/6010 B2.2 
14Sodium,mg/LUS EPA SW 846/6010 B1.4 
15Zinc,mg/LUS EPA SW 846/6010 B0.15 
16Molybdenum,mg/LUS EPA SW 846/6010 B0.07 
17Boron,mg/LUS EPA SW 846/6010 B0.1 
18Beryllium,mg/LUS EPA SW 846/6010 B52 

METALS

Sl#Test DescriptionTest MethodPQL
1Mercury,µg/LUSEPA 245.1/CHM SOP-076E-040.51

BTEXN & TPH

WASTE WATER

Oily Water Effluent water sampling and collection – (For Disposal)

DM EFFLUENT (EPSS) – Each

Sl#Test DescriptionTest MethodPQL
1Aluminum,mg/LAPHA 3120 B0.18
2Appearance,APHA 2110–
3Arsenic,mg/LAPHA 3120 B0.34
4Biochemical Oxygen Demand,mg/LAPHA 5210 B2.0
5Cadmium,mg/LAPHA 3120 B0.15
6Chemical Oxygen Demand,mg/LAPHA 5220 B1.0
7Chromium,mg/LAPHA 3120 B0.1
8Cobalt,mg/LAPHA 3120 B0.10
9Copper,mg/LAPHA 3120 B0.13
10Flash Point (COC),° CASTM D-92 
11Free Oil,%APHA 5520 B0.1
12Lead,mg/LAPHA 3120 B0.08
13Manganese,mg/LAPHA 3120 B0.18
14Mercury,µg/LUSEPA 245.1/CHMSOP-076E-040.51
15Nickel,mg/LAPHA 3120 B0.16
16Nitrogen (Ammonia),mg/LAPHA 4500 NH3 F0.01
17Oil and Grease (Emulsified),mg/LAPHA 5520 B5.0
18Selenium,mg/LAPHA 3120 B0.44
19Silver,mg/LAPHA 3120 B0.14
20Sulfates,mg/LAPHA 4500 SO4²¯ E1.0
21Total Dissolved Solids dried @ 180° C,mg/LAPHA 2540 C10
22Total Heavy Metals,mg/LAPHA 3120 B / Calculation–
23Total Sulfides,mg/LAPHA 4500 S²¯ F1.6
24Total Suspended Solids dried @ 103 – 105° C,mg/LAPHA 2540 D10
25Zinc,mg/LAPHA 3120 B0.51
26pH Value,APHA 4500 H+ B0.1

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Chilled and Domestic Water Testing in Dubai, UAE

Enquiry:

Please quote for testing of below scope

Department
Domestic water and chilled water testing
S.No.DescriptionQTYUOM
1Domestic water-Micro(Heterotrophic plate count, Total Coliforms,
Pseudomonas Aeruginosa, Fecal Coliform
Enterococci
15sample
2Domestic water-Legionella Pneumophila, Serogroup 1 and
Legionella serogroup 2 to 14
15sample
3Domestic water-chemical analysis(pH, TDS, Chlorine, #Bromate)15sample
4Chilled water chemical analysis(pH,Conductivity, TDS, Suspended solids, Sodium Nitrite, total Iron)8sample
5Chilled water-Micro(Heterotrophic plate count, Total Coliforms,
Pseudomonas Aeruginosa, Fecal Coliform
Enterococci
8sample
6Chilled water-Legionella Pneumophila, Serogroup 1 and
Legionella serogroup 2 to 14
8sample

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Beverages, Soft Drinks, Energy Drinks Testing in Dubai, UAE

Enquiry:

I would like to know if your laboratory does the sugar level test (total sugar quantity and sugar profile) on beverages (soft drinks, energy drinks, any sweet drinks). Also if you do the artificial sweeteners test on the beverages.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Rapeseed Oil, Flaxseed Oil, Animal Feed Testing in Abu Dhabi, UAE

Enquiry:

 I am writing to inquire about laboratory testing of peas, rapeseed oil, flaxseed oil and animal feed. Could you please tell if you take these kinds of product tests? I would also like some information on how much does it cost and what amount of the product is needed for the testing?

Is it possible to take tests in the UAE? Do you have office here?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].