Chemical Analysis of RO Water in Jubail, KSA

Enquiry:

 We require quotation for chemical analysis as per below parameter with delivery schedule & payment Terms at the earliest for our Project,   

 1, Chemical analysis for RO and Camp Water: (Parameter – pH value, Appearance, Oduor, EC, TDS, TSS, Total Hardness, Total Alkalinity, Cl, SO4, Ca, Mg, HCO3, NO3, SiO2, Fe, Cu, Zn, Na, K & Mn.) 

 ————–


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Barrier Fluid Testing in Jubail, KSA

Enquiry:

We need your services to identify physical and chemical properties of barrier fluid oil FDA 22.

We have the oil samples with us in Jubail Saudi Arabia.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Fuel Oil Testing in New York, USA

Enquiry:

Can we have a laboratory get back to us for #6 Fuel Oil Testing?

Our needs are somewhat specific.

There are many ways to analyze number 6 fuel oil.

Below are the parameters we need to fulfil for our client

Below is our requirements:

Bunker Fuel Adultrant Testing    ISO 8217
SulphurASTM D4294-21 ASTM D4294-21ASTM D5453ISO 8754 XRF
Sulphur    ISO 14596 XRD
API GravityASTM D0287-22 ASTM D2827ASTM D287 
Specific Gravity   ASTM D1298 
Viscosity   ASTM D445 
Viscosity Index   ASTM 2270 
Kinematic Viscosity    ISO 3401
Density Hydrometer   ISO 3675ISO 3675
Density  Oscillating U-Tube   ISO 12185ISO 12185
% Water Karl Fischer   ASTMD6304CISO 12937
Water Content    ISO 3733
Pour Deg FASTM D97-17b (2022) ASTM D5950ASTM D97ISO 3016
% WeightASTM D4870A    
% WeightASTM D4870B    
Ash % WeightASTM D482 ASTM D482ASTN D874ISO 6245
Carbon Residue    ISO 10370
VanadiumIP-501EPA 6010C  IP-501
SodiumIP-501EPA 6010C  IP-501
CalciumIP-501EPA 6010C  IP-501
PhosphorousIP-501EPA 6010C  IP-501
ZincIP-501EPA 6010C  IP-501
AluminumIP-501EPA 6010C  IP-501
SiliconIP-501EPA 6010C  IP-501
LeadIP-501EPA 6010C  No
Nickel    IP-501
Iron    IP-501
FlashpointEPA 1010  ASTM D92 
Flashpoint(Pensky)   ASTM D93ISO 2719
Flashpoint-Rapid Equilibrium    ISO 3679
PAH ContentASTM D5186EPA 8270D   
Fuel FingerprintEPA 8015M    
TCLP Metals1311/6010C/7470A1311/Total EPA 200 series   
PCBsEPA 8082EPA 608.3   
ReactivitySW-846, Sec 7.3    
Paint Filter TestEPA 9095B    
Bottom Water&Sediment   ASTM D2709ISO 10307 – 1&2
Acid Number    ASTN D664-09
pHEPA 9040  ASTMD1287 

When you have a chance can you send us a referred laboratory for the below?


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Stucco and BMA Testing for Gypsum, India

Enquiry:

As discussed, Request you to share quotation for Stucco and BMA for Gypsum

Please find the below for your reference.

ParametersMethod
Calcium as CaOASTM C 471
Magnesium as MgOASTM C 471
Silica as SiO2SGS/MIN/SOP/008 (Based on ASTM C 25-19)
Iron as Fe2O3SGS/MIN/SOP/009 (Based on ASTM C 25-19)
Aluminium as Al2O3SGS/MIN/SOP/009 (Based on ASTM C 25-19)
Sulphate as SO3ASTM C 471
Combined Water (215 – 2300C)ASTM C 471
Moisture (Free Water)ASTM C 471
Chloride as NaClASTM C 471
Purity based on SO3 (CaSO4.2H2O)IS 1288
pH (10% Solution)By pH Meter
Specific Surface Area/Blain Value 
BMA Efficiency 

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

pH Meter Calibration in Singapore

Enquiry:

Please kindly help to quote for calibration with MU under ISO17025 for the following: (Including collection and return of equipment)

1) pH Electrode with Temperature together with the pH Meter

Model: FSP#13-620-AP50A


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Sea Sediment Analysis in Muscat, Oman

Enquiry:

Can we have your quotation for Sea Sediment Analysis, for the following parameters:
• Faunal Analysis
• Redox Potential
• Particle size analysis
• Carbon and Nitrogen contents
• Heavy metal analysis including copper, lead, and cadmium levels

Kindly please inform us if your laboratory can perform this testing and if so, please prepare a quotation from your end.

———-

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].



HSFO and Refinery Feedstock Testing in Duqm, Oman

Enquiry:

With reference to the above subject matter, we are looking for the following test for our Duqm Project –

Fuel Oil (HSFO) and refinery oil feedstocks for H2S content – using Seta H2S Analyzers and test method IP-570 (ASTM D-7621), providing important fuel hydrogen sulfide data for safer storage and transportation.

The IP-570 test method is the only test method allowed in ISO-8217 for determination of H2S in fuel oil.

Please let us know your interest to perform the test. If you find this fall under your scope of work, you are requested to please provide your commercial terms & conditions in detail with sample collection, duration of conducting the test & time frame of provision of result at the earliest.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].