Lubricating Oil Test Slate – SATORP Specification/ Maaden Specs
Lubricating Oil Test Slate | ||
1 | Used Lube Oil Analysis- SATORP Slate | |
2 | Used Lube Oil Analysis MAADEN Slate – A& C | |
3 | Used Lube Oil Analysis MAADEN Slate – A+ | |
4 | Used Lube Oil Analysis MAADEN Slate – A+ (Without Particle count) | |
5 | Used Lube Oil Analysis MAADEN Slate – B | |
6 | Engine Lubricating Oil Analysis – PEAX Slate | |
7 | Individual analysis rate for Lubricating Oil parameters | |
8 | Grease Analysis-slate |
Lube Oil Test Slate Expansion
Used Lube Oil Analysis – Satorp Slate
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Contamination code (Particle count analysis) | NAS 1638 /ISO 4406aa | |
6 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
7 | Neutralization Number (Total Acid Number) | ASTM D974/D664 |
Used Lube Oil Analysis – Maaden Slate – A & C
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Foaming Characteristics | ASTM D 892 | |
6 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
7 | Neutralization Number (Total Acid Number) | ASTM D974/D664 |
Used Lube Oil Analysis Maaden Slate– A+
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Contamination code (Particle count analysis) | NAS 1638 /ISO 4406 | |
6 | Foaming Charecteristics | ASTM D 892 | |
7 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
8 | Neutralization Number (Total Acid Number) | ASTM D974/D664 | |
9 | Flash Point | ASTM D92 | |
10 | Fire Point | ASTM D92 |
Used Lube Oil Analysis Maaden Slat – A+ (Without Particle count)
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Foaming Characteristics | ASTM D 892 | |
6 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
7 | Neutralization Number (Total Acid Number) | ASTM D974/D664 | |
8 | Flash Point | ASTM D92 | |
9 | Fire Point | ASTM D92 |
Used Lube Oil Analysis Maaden Slate – B
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Foaming Characteristics | ASTM D 892 | |
6 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
7 | Neutralization Number (Total Acid Number) | ASTM D974/D664 | |
8 | Demulsibility (Water Separability) | ASTM D1401 |
Engine Lubricating Oil Analysis- Peax Slate
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 100° C | ASTM D445 | |
2 | Water percentage by Karl Fischer method | ASTM D6304 | |
3 | Base Number | ASTM D2896 | |
4 | FTIR- Soot/Nitration/Sulfation | ASTM E2412 | |
5 | Insoluble | ASTM D893 | |
6 | Metals & additives by ICP -21 elements (Al, Ba, B, Ca, Cr, Cu, Fe, pb, Mg, Mg, Mn, Ni, P, K, Si, Ag, Na, Sn, Ti, V, Zn) | ASTM D5185 |
Lube Oil Overall Parameters and Test Methods:
Sr. No. | Test Parameters | Test Method | |
1 | Viscosity at 40 o C | ASTM D445 | |
2 | Viscosity at 100 o C | ASTM D445 | |
3 | Viscosity Index | ASTMD 2270 | |
4 | Water percentage by Karl Fischer method | ASTM D6304 | |
5 | Contamination code (Particle count analysis) | NAS 1638 /ISO 4406 | |
6 | ICP Spectrographic for Metal elements, Additives, and Contamination Metals | ASTM D5185 | |
7 | Neutralization Number (Total Acid Number) | ASTM D974/D664 | |
8 | Base Number | ASTM D2896 | |
9 | FTIR- Soot/Nitration/Sulfation | ASTM E2412 | |
10 | Foaming Characteristics | ASTM D 892 | |
11 | Demulsibility (Water Separability) | ASTM D1401 | |
12 | Insoluble | ASTM D893 | |
13 | Flash Point | ASTM D92 | |
14 | Fire Point | ASTM D92 | |
15 | RBOT (Rotary Bomb Oxidation Test) | ASTM D2272 | |
17 | Wear Debris Analysis (Ferrography) | ASTM D7690 | |
18 | Air Release | ASTM D3427 | |
20 | Varnish Potential Index | ASTM D7843 | |
21 | Ruler Test (Note1) | ASTM D 6971 | |
22 | Rust Prevention Characteristic | ASTM D665 | |
23 | Boiling Range Distribution of Lube Base Oils | ASTM D7500 | |
24 | PQ Index | – | |
25 | Pour Point | ASTM D97 | |
26 | Trace Sediments | ASTM D 2273 | |
27 | Water Content | ASTM D 95 | |
28 | Odor | Organoleptic | |
29 | Insoluble | ASTM D 4898 | |
30 | Sulphated Ash | ASTM D 874 | |
31 | Density | ASTM D4052 | |
32 | Total Sulphur by EDXRF | ASTM D 4294 | |
33 | Blotter Spot Test | ASTM D7899 | |
34 | Fuel Gasoline Dilution | ASTM D3525 |