• Home
  • Archive by category "Lahore"

Transformer Oil DGA, Ageing, Furans Testing in Lahore, Pakistan

Enquiry:

We are currently preparing a commercial offer for our client, covering a 2-year transformer oil analysis contract by a foreign laboratory, we’d like to request a quotation directly from your team.

Scope of testing required:

1. Transformer Oil DGA Analysis (as per IEC 60567/60599) – 20 samples

2. Transformer Oil Ageing – Acidity, BDV, DDF (as per IEC standard) – 20 samples

3. Transformer Oil Paper Ageing – Furans & Methanol (as per IEC standard) – 14 samples

Additional scope requirements:

– 50% of samples tested in Year 1, remaining 50% in Year 2

– Supplier to provide sampling kits to our site team

– Supplier to arrange/advise on dispatch logistics of oil samples from Pakistan site to your nearest UAE facility

– A comprehensive technical report per batch, including interpretation of results, condition assessment, comparison against historical/online DGA data, and clear recommendations for corrective/preventive action

The 10 transformers involved are ___ and unit auxiliary transformers (220kV/22kV and 220kV/18.5kV/11kV class); full equipment list available on request.

Could you please share, or point us to the right regional contact for:

– Per-sample pricing for each test category

– Sampling kit cost (if chargeable)

– Estimated freight/logistics cost and lead time from Pakistan to your UAE facility

– Typical turnaround time per batch

– ISO/IEC 17025 accreditation scope covering these tests

Our submission deadline is 27 July 2026, so we would greatly appreciate a prompt response, ideally within 3-4 working days.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

TCLP Test for Beads Waste Disposal, Lahore, Pakistan

Enquiry:

We want to perform the TCLP test for the wastage of used aluminum oxide beads.

These beads are utilized for cleaning of metallic parts of turbocharger at beads blasting machine, pls check & share your quotation for this test.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Testing of Wet Sieving of Dye ISO787-18 in Lahore, Pakistan

Enquiry:

TESTING OF WET SIEVING OF DYE – ISO 787/18

We intend to have Yellow Dye tested for Sieving (Wet) to check percentage (%) retained on 250 micron sieve by wet sieving process.

Please let us know whether you can conduct this test.

Please also share testing fee and time required.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

PCB, Oil Level Sensor Transformer Oil Test in Pakistan

Enquiry:

I wanted to formally document the specific testing scope required for the Smart Controller PCB and the Oil Level Sensor.

As agreed, all procedures, criteria, and environmental parameters will strictly comply with IEC 60076-22-1 (Power transformers – Part 22-1: Electrical equipment – Standard accessories).

To ensure full compliance and regulatory safety for these transformer accessories, we will be conducting the following tests within the agreed 3-to-4-day window:

1. Dielectric & Insulation Testing

  • Insulation Resistance Test: To verify the integrity of the isolation between active electronic circuits and the chassis/ground.
  • Dielectric Test (Withstand Voltage): High-voltage stress test to ensure no electrical breakdown or flashover occurs under standard-defined test voltage levels.

2. Electromagnetic Compatibility (EMC) Immunity Testing

  • ESD (Electrostatic Discharge) Immunity Test: To evaluate the sensor and PCB’s resilience against direct and indirect static discharges.
  • EFT/Burst (Electrical Fast Transient) Test: To ensure the controller’s electronics remain stable and unaffected by rapid transient spikes on power or signal/telemetry lines.
  • Surge Immunity Test: To verify heavy-duty surge protection against high-energy overvoltage events (such as switching transients or simulated lightning surges).

3. Additional Specific Verification (per IEC 60076-22-1)

  • Ingress Protection & Environmental Performance: Ensuring the physical enclosures of the sensor/controller maintain their required IP ratings (typically IP66) and operation tolerances under specified transformer ambient and oil temperatures.
  • Contact Performance Verification: Ensuring the signal/alarm contacts reliably actuate without chatter or latching failures under normal and high-stress conditions.

IEC Document and product picture are attached above for your further assistance.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube Oil Testing in Lahore, Pakistan

Enquiry:

please share the quotation for lube oil analysis for below parameters.

1. Acid number

2. Viscosity at 40 degC

3. Viscosity index

5. Water content (ppm)

6. Metal analysis (ppm) (ZN, Cu, Fe, Ca, Si, Al, Pb) 7. Density at 15 degC


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Olive Oil Quality Testing in Pakistan

Enquiry:

I am producing olive oil through cold-press extraction in Pakistan using locally sourced wild olive seeds, which are small in size and dark in color. I would like to have a sample of this oil tested for quality and purity.

Kindly provide the following information:

  1. The required quantity and packaging guidelines for the sample.
  2. The address where the sample should be sent.
  3. The estimated time required to complete the testing and deliver the report.
  4. The total cost for a full olive oil analysis, including any optional parameters or urgent processing charges.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].