Grease Mixed Transformer Oil Testing in Dammam, KSA

Enquiry:

We are manufacturing Power Transformer filled with Transformer oil as per IEC 60296. Recently we had observed that the one of transformer installed at site filled with oil color has turned to black without any electrical failure.Please let us know your expertise in diagnosis this and We want to know basic content mixed in oil. If you have or recommend any test available, please let us know. The oil is available at Dammam in Saudi Arabia.

Following are the some pictures for your reference to understand.


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Insulating Oil Testing in Tabuk, KSA

Enquiry:

please provide your favorable quotation for the TRANSFORMER OIL SAMPLE TEST.

1. Laboratory Testing of Insulating oil for 1 40MVA Auxiliary Transformers, including the attached requirements – 7 Samples.

2. Laboratory Testing of Insulating oil for station service transformer, including the attached requirements – 8 samples. 


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing in Eastern Province, KSA

Enquiry:

We are a contractor providing electrical solutions and services, including medium- to low-voltage and automation, in Saudi Arabia. We will participate in some of the preventive maintenance shutdowns for the power transformer. I think part of the scope involves an oil analysis, which requires your expertise, and we are planning to outsource this task. In this regard, and as part of our planning for this scope, we would like to inquire about the expected duration for the release of results upon provision of samples for a transformer oil analysis with the following data:

  • 1.Color ASTM D1500.
  • 2.Total Acid Number, ASTM D974.
  • 3.Interfacial Tension ASTM D971.
  • 4.Water Content, ASTM D1533.
  • 5.Breakdown Volt (1/2), ASTM D1816.
  • 6.Power Factor, ASTM D924.
  • 7.Dissolved gas, ASTM D3612-C.
  • 8.DBDS, IEC 62697-1.
  • 9.Passivator, CIGRE WGAZ.32 TF02.
  • 10.Furan Compounds, ASTM D5837.
  • 11.Cover Cond Deposit, IEC 62535.

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Analysis in Dubai, UAE

Enquiry:

Please share the quotation for the oil lab testing. (Sample report attached) along with that DGA also required.

Physical Test

Colour
Appearance
Dielectric Break Down Voltage
Water Content
Dielectric Dissipation Factor @ 90°C
Resistivity@90°C
Acidity (Neutralization Number)
Interfacial Tension
Corrosive Sulphur
Passivator
DBDS (Dibenzyl Disulphade)

Dissolved Gas Analysis (DGA)

Nitrogen
Oxygen
Carbon Dioxide
Carbon Monoxide
Hydrogen
Methane
Ethane
Ethylene
Acetylene

Total Combustible Gases
Total Dissolved Gases

Furans Test

5 – Hydroxymethyl -2 – Furfural
Furfuryl Alcohol
2 – Furaldehyde
2 – Acetylfuran
5 – Methyl – 2 – Furfural
Total Furan


One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Power Transformer Oil Testing in Suez, Egypt

Enquiry:

We are a company located in Suez, Egypt a leader company in FMCG industry.

We own a 10-power transformer as per the list attached and required to do the following tests:

  • Transformer DGA Testing
  • Full Analysis of Transformer Oil

One of our highly proficient and ISO certified laboratory would be taking over this job.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].