• Home
  • 2021
  • September
  • 15

Diesel Storage Tanks Calibration, Flow Meter Calibration, UAE

Enquiry:

Kindly be informed that our company has recently bought a terminal location in UAE.

We need to calibrate 3 cylindrical fixed roofs diesel tanks of capacities: 

  • 150,000 IG (Diameter: 7.64 m | Height: 16 m)
  • 150,000 IG (Diameter: 7.64 m | Height: 16 m)
  • 60,000 IG (Diameter: 6 m | Height: 12 m)

No previous calibrations were made on the tanks, and they are currently empty.

You can find attached a plan, an elevation and a section through the tanks.

You can also find a photograph showing a general view of the tanks.
Please note that each of the 3 tanks is equipped with one manhole at the top and another one at the bottom.

In addition, we need to calibrate 6 flowmeters manufactured by Liquid Controls:

  • 3 x Model M-30-1 (2 flowmeters are installed on the tanks and 1 flowmeter is installed on a truck)
  • 2 x Model M-15-1 (both installed on trucks)
  • 1 x Model M-7-1 (installed on a truck)

Could you please provide us with a quotation for the needed works ?


One of our highly capable and competent branch in Dubai would be carrying our huge storage tanks calibration and Flow Meters Calibration.

Water Testing Annual Contract, Bahrain

Enquiry:

To carry out water sample Microbiological Analysis Testing and  report submission for one year.

Total tests per year 24 ( 2 monthly tests  x 12 months )

NOTE
1. Following minimum Parameter to be Included in the water testing Report.
Parameters – Total Coliforms (Test Methods- ISO 9308-1:2014), Pseudomonas  aeruginosa (Test Methods- ISO 16266:2006),

Total Plate Count @37 Deg. C (Test  Methods- APHA 9215 B)
2. The Reports shall be from IAS (or equivalent) standard approved/accredited agency.
3. Total two Sample to be collected for analysis and submission of report every month.
4. Specialist to submit detailed report if any parameters are not within desired limits of acceptable potable water requirement and advise for counter measures needed to bring the parameter within limit.
5. Specialist to collect the sample and submit original test report  /analysis original documents to company.


One of our highly competent and ISO certified lab would be taking over this annual contract.

Palm Oil and Coconut Oil Testing Contract Hungary

Enquiry:

I turn to you with the following question
We are looking for an accredited laboratory of testing palm oil trans fatty acid.
Our company produces vegetable fats in Hungary, Szekszárd. We manufacture mainly palm- and coconut oil and their fractions.
We would like to send a sample for testing monthly.


One of our competent lab for edible oil testing would be carrying out fatty acid analysis.