Transformer Oil Testing in Iraq

Enquiry:

We have two auxiliary transformers installed at PG Plant. In accordance with the maintenance schedule, transformer

oil needs to be tested. Below are the details of the test.

  1. DGA
  2. Dielectric Test

Transformer details as under.

  1. Auxiliary Transformer 2000Kva/6300V/400V
  2. Auxiliary Transformer 1250Kva/6300V/400V

One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Lube, Grease, Transformer oil Analysis in Jeddah, KSA

Enquiry:

Please send us your competitive oil analysis offer for the attached files for the purpose of an annual contract.

Transformer Oil:

Sr. No.Test ParametersTest MethodUnit Price (SAR)
1ColorASTM D1500 
2AppearanceASTM D1524 
3Acidity (Neutralization  Number)ASTM D974 
4Interfacial TensionASTM D971 
5Water ContentASTM D1533 
6Dielectric break down Voltage 2.5mm gapASTM D877 
7Dielectric break down Voltage 1 mm gapASTM D1816 
8Dielectric break down Voltage 2.5 mm gapIEC 60156 
9Dielectric Dissipation Factor @90°IEC 60247 
10Oxidization Stability 72 Hours @110°IEC 61125C 
11Oxidization Stability 164 Hours @110°IEC 61125C 
12Power Factor at 25°ASTM D924 
13Power Factor at 100°ASTM D924 
14Copper Corrosion @150 ° for 48 HoursASTM D1275 B 
15Specific Gravity at 60/60°ASTM D1298 
16Flash Point COC °ASTM D92 
17Dissolved Gas by GC (IEEE Std)ASTM D3612 
18Viscosity @40°ASTM D445* 
19Polychlorinated Biphenyls (PCB’s) by GCASTM D4059 
20Pour PointASTM D79 
21DBDSIEC 62697 
22CCDIEC 62535 
23PassivatorIEC 60666 
24Particle countASTM D6786** 
25Trace Metals (Cu, Fe, Al, Ni, Zn, Si, Na, Ca, Mg)ASTM D7151 
26FURAN Compound (5 compounds)ASTM D5837 
 
27Oxidation inhibitor by GCASTM D4768 
28Oxidation Stability by RBOTASTM D2112 
29Sediment and Soluble SludgeASTM D1698 
30Specific Resistance @25 Deg CASTM D1169 
31Specific Resistance @90 Deg CASTM D1169 
32Degree of PolymerizationASTM D4243 
33Degree of Polymerization (Calculation)***Calculation 
34Refractive IndexASTM D1218 
35Total SulfurASTM D4294 
36Oil Profile TestASTM D2140 

Grease Testing:

Lube Oil Testing:


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing in Jeddah, KSA

Enquiry:

We are pharma factory based in Jeddah looking for a professional and certified contractor to preform oil analysis of our 8 Factory distribution transformers.  Below are details :

Manufacturing name : ABB

Manufacturing Year : 2010 – 2016

Transformer rating from (1000 kva – 2000 kva) .

please contact me for any further information on our system.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Testing in Bangladesh

Enquiry:

Here is the attach file of transformer Oil testing service details . If you have those service, please give us the technical working details with commercial offer of that services…And please inform us the Sub-Continent Branch of Bangladesh Contact No. and mailing Address…

SL No.  Service PR  No. Service  Name  Service  Description  Unit of measure  1 3500002366  10-14MVA Trafo’s Oil Test  BDV test for (main tank) AU (Astronomical units)  2 3500002366 Dissolve gas analysis test (main tank) AU (Astronomical units)  3 3500002366 Moisture test (main tank) AU (Astronomical units)  4 3500002366 BDV test for (conservator tank) AU (Astronomical units)  5 3500002366 Dissolve gas analysis test (cons. tank) AU (Astronomical units)  6 3500002366 Moisture test (cons. tank) AU (Astronomical units) 


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil Analysis in Oman

Enquiry:

I want to enquire your services for transformer oil tesing. We have 33kV 6.3MVA transformers at site and we want to carryout the test mentioned below:

1. Breakdown Voltage Test

2. Dissolve Gas analysis Test

3. Water Content in Oil

I want to let you know that we have around 89 Transformers at our site and we want to perform their oil tests in different batches. Like in the first batch we would like to do testing for 10 Transformers. 

So I want the best quotation, that attract us in terms of price, from your side. 

Case 1: Quotation when we deliver Oil sample to your lab

Case 2: Quotation when your team come to site and take the sample and do the testing at lab.

case 3: Quotation when your team come to site and take the sample and do the testing at site


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

Transformer Oil DGA, Oil filtration Test in Oman

Enquiry:

Please request a competitive offer for the For Transformer Oil DGA Analysis & Oil Filtration in power Plan.

Your immediate response will be appreciated and please feel free to contact me for clarification on this matter.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].

DGA Testing in Abu Dhabi

Enquiry:

Please share the quotation with the best price for the DGA test of the oil-type transformer in Abu Dhabi. Please also share your contact details for Abu Dhabi.


One of our highly proficient and ISO certified laboratory would be taking over this testing.

Should you have any similar requisites, do drop us email and we shall revert instantly -> [email protected].